Globe GHP12G Скачать руководство пользователя страница 8

Page 8

Operating Instructions

Operating the Hot Plate - Pilot Lighting Instructions

Before operating the hot plate, it should be checked to see that it is sitting level. Adjust the feet to level the hot 

plate. Be sure the catch tray has been properly placed.

The pilot lights on the appliance have been set at the factory. Each burner has a pilot light.

 

1.   Make sure all knobs are in the “OFF” position.

 

2.  The main gas valve should be “CLOSED/OFF” for five (5) minutes prior to lighting pilots to clear   

 

 

any existing gas.

 3. 

Turn the main gas valve to “ON/OPEN”.

 

 

4.  Light and hold an ignition source (match) at the pilot. When the flame is established, remove the 

 

 

ignition source. Repeat this step for each burner as each burner has its own individual pilot.

  The pilot can be reached through the holes in the front of the unit. 

 

5.  Turn each burner knob “ON”. If the burners do not ignite promptly, turn the knobs “OFF”. From the

 

 

opening in the front panel, use a screwdriver and turn the pilot valve screw counterclockwise which will

 

 

increase the flame height, and then repeat step 4.

 

 

The pilot flame should be as small as possible, but large enough to guarantee reliable ignition of the

 

 

burners when the knobs are turned to “ON”. The holes located in the front panel are pilot valve

 

 

adjustments. Use a screwdriver to turn the valve to adjust the flame height 

to your desired level. 

Igniting the Burner

To ignite the burner, turn knob to the “ON” position. Then back off to the desired flame level. The range of 

adjustment is virtually infinite between “ON” and “OFF”. 

The space between the legs at the bottom admits combustion air. DO NOT BLOCK THIS SPACE.

All burners are lit from constantly burning pilots. Turning the valve to the desired flame height is all that is required 

to put the unit in service.

Do not permit fans to blow directly at the unit. Wherever possible, avoid open windows next to the unit’s sides or 

back. Avoid wall type fans which create air cross-currents within a room.

It is also necessary that sufficient air be allowed to enter the room to compensate for the amount of air removed 

by any ventilating system. Otherwise, a subnormal atmospheric pressure will occur, affecting operation and 

causing undesirable working conditions.

A properly designed and installed hood will act as the heart of the ventilating system for the room or area in which 

the unit is installed, and will leave the unit independent of changing draft conditions.

NOTE: It may be necessary to adjust the balance of gas, volume and air supply to each burner. This must be done 

by an authorized service technician.

Содержание GHP12G

Страница 1: ...company Visit our website for information on additional products available from Globe www globefoodequip com Slicers Mixers Countertop Cooking Equipment Meat Choppers Scales This manual contains impor...

Страница 2: ......

Страница 3: ...299 4147 E MAIL info globefoodequip com WEBSITE www globefoodequip com Globe Food Equipment Company 2014 03042014 Ver 1 Rev 1_2014 Index WARRANTY REGISTRATION SCAN THE QR CODE WITH YOUR MOBILE DEVICE...

Страница 4: ...nnel come in contact with this equipment Please remember that Globe cannot anticipate every circumstance or environment in which this equipment will be operated It is the responsibility of the owner a...

Страница 5: ...SA B149 2 as applicable and in accordance with local codes The appliance and its individual shutoff valve to be supplied by user must be disconnected from the gas supply piping system during any press...

Страница 6: ...INSTALLATION ON NON COMBUSTIBLE SURFACES ONLY Non combustible clearances 6 sides 152 mm 6 rear 152 mm 4 floor 102 mm 8 Do not obstruct the flow of combustion and ventilation air under the unit by the...

Страница 7: ...e when servicing or adjusting any parts or attachments and before cleaning Never leave the hot plate on overnight Do not operate any equipment with a damaged or leaking gas line ignitor or valves or i...

Страница 8: ...are turned to ON The holes located in the front panel are pilot valve adjustments Use a screwdriver to turn the valve to adjust the flame height to your desired level Igniting the Burner To ignite the...