5 kW
RRF - 40071329
008-CPR-2013.06.10
3 - 7 kW
80,9 %
5 kW
CO-Emission: 1250 mg/Nm³ - 799 mg/MJ
.Efficiency
Stove Pluto ST 0311
25292
Tested stove Type 1: EN 13240: 2001+A2: 2007
Type
Heat output / Energy efficiency
.Nominal heat output
Fuel
Test-Nr.
Side: 40 cm
Rear: 20 cm Bottom: 0 cm
Front stove window: 80 cm
.Minimal distance to
flammable materials:
Reading and follow up of given guidelines in the manuel
The connection of more stoves to one chimney is permitted
Wood and coal Time burning
Approved German tests and CE mark EN 13240:2001 + A2:2007, according
DIN
plus
and also according Art. 15A B-VG Ö-Norm Austria.
1. and 2. level 1. BimschV Germany and also Luftreinhalte-Verordnung
Switserland.
VKF Switserland
Globefire Ch.Leibfried GmbH, An der Bundesstraße 2,
D-49733 Haren / Ems, Germany
- Globe fire -
Declaration of performance Nr.
Test institute Number
15
Fulfilled
.Heat output
.Room efficiency
Mechanic solidity
Surface temperature
Combustion products
.Flue gas temperature
Fire safety
.Fire behavior
1625
Dust in Mg on 13% O2: 37 mg/Nm³
Values (converted): 33 mg/MJ
Nox: 116mg/Nm³
CO: 1250 mg/Nm³
OGC:51 mg/Nm³
73 mg/MJ
799 mg/MJ
32 mg/MJ
Fulfilled
Fulfilled
Fulfilled
236 °C
A1
12.
Globe Fire
recommendations
Lighting the fire:
Open the primary / secondary air vent.
Check to see if an eventual air vent or
pipe in your burner is open.
1. Open the fire / grid.
2. Place two large logs (10 cm thick) on the
fire grid completely covering the grid.
Use a round log or chopped wood.
3. Place a firelighter in the middle.
4. Light the firelighter.
5. When the firelighter starts to burn place two
large logs (10 cm) in the flames.
Close the door.
When the stove is hot (approx. 15 - 30 minutes)
close the grid.
Add further wood using 1, 2, or 3 logs. Make sure
the wood has a real glow of flames before doing
this. (to prevent smoke in the room)