background image

Safety regulations

The user must consult the user’s manual for instructions on operating
and using the stove

The stove has been tested according to German regulations and has
acquired the Bauart 1 test.
This offers the possibility of connecting more than one burner to a 
single chimney.
The chimney sweeper should be consulted about this.

When the stove is in use the door must be closed.
The fire can be regulated by the revolving grid and the primary /
secondary air regulator.
Do not close the primary / secondary air regulator before the wood has 
burnt to a glow and the flames are no longer visible.

In houses where air supply (necessary for the fire to burn) is taken from
the room, there should be a sufficient supply of fresh air.

The ash door should always remain closed when the fire is burning.
If the door is left open an uncontrollable amount of air is added to
the fire which may prove dangerous as the stove can become 
overheated.
Parts that are in contact with the fire could buckle or even break.

When the stove is not used for a longer period of time, close the 
revolving grid and the primary / secondary regulator.
This is to ensure that any ash or smell of burning does not enter the
house.

WARNING:  CHILDREN PLAYING !!!
                     A stove becomes very hot when it is burning !!!

2.

1.  INSTALLATION OF STOVE.

The stove is ready for use and can be connected to the chimney with the flue pipe.
If possible, connect the flue pipe, keeping it short, straight or slightly at an angle to
the chimney.

Seal the connection (heat resisting fire rope).
When fitting the legs do not drag or push the stove but lift it (the legs could break off).
Connect the external air flow by using a pipe.
 
National or European standards, including local standards and any fire 
regulations must be complied with.
Ensure that there is sufficient air flow before burning wood.
This is particularly important in well insulated houses and those with a mechanical
ventilation system.

To ensure your chimney has the correct measurements it is possible to measure
it. Ask your chimney sweeper for advice.

Before placing the stove into position check to see if the floor can take the weight.
When in doubt place the stove on a large slab of stone or marble to divide the 
weight.

2.  GENERAL FIRE SAFETY INSTRUCTIONS.

During wood burning, high temperatures are reached make it impossible to  
touch the top, sides or door without using heat resisting gloves.

Children must be made aware of the dangers and kept away for the stove
when lit.

3.

         Installation and operation manual for Stove model ST-0311 
    Tested according to German standards: DIN EN 13240, Ö-Standard
15A and 1.+2. BimschV., CE and Luftreinhalte-Verordnung Switzerland   

Содержание Pluto ST 0311

Страница 1: ...User s manual Pluto An der Bundesstra e 2 49733 Haren Ems Germany Tel 49 0 5932 7334784 info globe fire de...

Страница 2: ...d production of stoves insert fires and cookers Our models are all made of a high quality cast iron using advanced technology enabling you to burn your fire for long periods Please read the User s man...

Страница 3: ...tove becomes very hot when it is burning 2 1 INSTALLATION OF STOVE The stove is ready for use and can be connected to the chimney with the flue pipe If possible connect the flue pipe keeping it short...

Страница 4: ...15 to 20 min Before starting the fire check to see that all air vents are open When the fire is burning well the fire grid can be closed and the flames regulated with the primary secondary regulator...

Страница 5: ...is 20 cm From both sides 40 cm From the glass 80 100 cm Floor A flammable floor carpet wood etc must be protected by a fireproof plate that is 30 cm wider on both sides and at least 50 cm in front Eac...

Страница 6: ...add more wood after first wood has burnt to a glow 9 8 GUARANTEE 30 months guarantee This guarantee is only valid under normal use of the fire and for the operation of the stove It does not cover over...

Страница 7: ...ction pipe 4 Stove window 5 Fire rotating grid 6 Cinder guard 7 Ash pan 8 Primary Secondary regulator 9 Cooking plate 10 Air vent pipe 11 Ash guard 12 External air flow rear PARTS 9 10 11 11 85 275 36...

Страница 8: ...ation of performance Nr Test institute Number 15 Ful lled Heat output Room ef ciency Mechanic solidity Surface temperature Combustion products Flue gas temperature Fire safety Fire behavior 1625 Dust...