GUARANTEE :
26.
Globe- fire
provides the buyer with a guarantee within the context of the
legal regulations. The guarantee period of two years begins on the date
shown on the actual transfer. The invoice must be produced as evidence.
In the case of a defect which occurs within the guarantee period the
following will apply: Globe-fire will either repair the defect as soon as
possible, improve it or replace the part causing the defect. Termination of
the agreement or reduction of price is not possible unless this does not
comply with legal regulations. Only spare parts approved by the
manufacturer may be used.
Damage to the purchased appliance which may occur during normal use
( wear of the parts which are in contact with the heat, e.g.: fire room
covering, fire grate, ignition cartridges, burning pots, rust, varnish, brake
plate, sensors, glass, sealing, handles) is not included in the guarantee.
Any maintenance which has been neglected or inadequately carried out,
an incorrect chimney draught or one which has not been sufficient or too
strong, inappropriate use, carelessness or any change to the appliance
will not be included in the guarantee.
The initial installation of the appliance must be carried out by a trained
and qualified technician, recognized by us as a service partner. In the
case of structural changes to the stove or use of the stove which is not in
accordance with its intended purpose the guarantee will be void.
JACOBUS
CS 19-0040729-01
Pellet stove: EN 14785:2006
Type
Heating capacity /energy performance
Fuel
Test-Nr.
Side: 25 cm
Back: 10 cm Bottom: 0 cm
Front stove window: 100 cm
.Minimal distance to flammable
parts:
Read and follow the given instructions in the user's manual
Wood pellets
Tested according to DIN EN 14785:2006,
15A B-VG/ VKF 2nd faze of the BimschV Germany
Globefire Ch.Leibfried GmbH, An der Bundesstraße 2,
D-49733 Haren / Ems, Germany
- Globe fire -
Declaration of performance Nr
Heating in a building without heating and without
using warm water systems
Test institute number
18
Achieved
.Heating capacity
Nominal capacity: 88 % Shared capacity: 90,0 %
2,8 - 9,5 kW
Surface temperature
Emission combustion products
(at 13% 02)
.Flue gas temperature
Burning realibility
.Method of burning
IMQ SPA NB 0051
CO: 122 mg/Nm³
NOX: 98 mg/Nm
192 °C
A1
³
Voltage: 230 V
Frequency: 50Hz
Nominal capacity Max. 320 W
LED
Nominal capacity: 8,0 kW Shared capacity: 2,5 kW
021-CPR-2019 02.20
.Performance
.Capacity
Mechanical solidity
Achieved
Achieved
Achieved