Set low battery rate command
Byte
Bits
Parameter
Description
0
0
– 7
Leader
Always a value of 0xAA.
1
0
– 7
Length
0x07
2
0
– 7
Command Code.
0x82 = Set low battery track rate command
3 - 4
0 - 15
Rate
Rate in minutes, MSB first
5 - 6
0
– 15
CRC
Response:
AA 05 82 <CRC>
4.2.2.31
"Query Low Battery Rate"
Query low battery rate
Byte
Bits
Parameter
Description
0
0
– 7
Leader
Always a value of 0xAA.
1
0
– 7
Length
0x05
2
0
– 7
Command Code.
0x83 = Query battery track rate
3 - 4
0
– 15
CRC
Query low battery rate response
Byte
Bits
Parameter
Description
0
0
– 7
Leader
Always a value of 0xAA.
1
0
– 7
Length
0x07
2
0
– 7
Command Code.
0x83 = Query low battery track rate