9
5. POSITIONING
AND
INSTALLATION
The Quick Pull is a fixed hydraulic power lift that must be permanently
installed in a pre-established well-lit location, which is sheltered from the
atmospheric elements and free of flammable gases or vapours. The
hydraulic power lift must be installed at floor level and fixed with the
supplied anchoring screws.
The cement flooring, upon which the hydraulic power lift will rest, must be
level and integral and must possess suitable load-bearing characteristics.
The reinforced concrete must have a load bearing capacity of at least 300
kg/cm2, a concrete class of no less than 300 rbk and a cast depth of no less
than 200mm. All of the tubes and electrical cables for connecting the
hydraulic power lift’s base to the mobile control unit must be:
positioned in such a way so as to not be damaged during positioning.
covered by the metallic Omega protection which can be supplied upon
request
Note. The hydraulic power lift must be fastened to the ground with the
appropriate supplied “anchoring screws”.
ATTENTION
Failure to comply with this mandatory requirement could lead to
risks of load tipping with potentially serious consequences for
people and objects.
In cases where, during the installation of the hydraulic power lift,
the supplied cables result as not being of sufficient length, the
electrical connections must be redone without splicing the cables.
The hydraulic power lift’s intake air pressure must not be less than 8
bar.
The control unit must be positioned at least 3,000 mm from the edge of the
hydraulic power lift.
The operator is likewise required to only use the button panel at a safe
distance from the hydraulic power lift (at least 3,000 mm), and always from
the front of the structure, in order to avoid the risks associated with
potential lateral load capsizing.
The raising and lowering of the hydraulic power lift must always be
monitored by the operator. The operator must immediately arrest the
manoeuvre in the improbable event of load shifting.
Attention: No obstacles must be located behind the operator which could
impede the operator from distancing himself/herself from the machine in the
event of immediate danger.
Содержание Quick Pull
Страница 1: ......
Страница 2: ......
Страница 6: ...6 2 2 Quick Pull Hydraulic Power Lift encumbrance dimensions ...
Страница 16: ...16 7 8 9 RIF CODE DESCRIPTION 7 GK3 CONTACTOR 8 GK4 TRANSFORMER 9 GK5 CIRCUIT ...
Страница 25: ...25 17 ANNEXES ...
Страница 26: ...26 ...
Страница 27: ...27 ...
Страница 28: ...28 ...
Страница 29: ...29 ...
Страница 30: ...30 ...
Страница 31: ...31 ELECTRICAL SYSTEM SCHEME ...
Страница 32: ...32 ELECTRONIC BOARD ...
Страница 33: ...33 HYDRAULICS SYSTEM SCHEME ...
Страница 36: ......
Страница 37: ......