Global M3 SYSTEM Скачать руководство пользователя страница 12

The  M3  System®  Delivery  Module         

12

Pickup Valve 

& Strainer 

When connecting the piping, ensure that o-ring 

has been placed  between threading nut and pick 

up valve as shown in Fig. 4. 
Pickup valve is assembled with a foot filter (strainer) 

that avoids sediment priming problems. Install 

pickup valve on the bottom of the tank. (Fig. 5)

PIPING CONNECTIONS

Suction hose 
connection

Suction hose should be as short as possible 

and installed in vertical position to avoid air 

bubbles when suctioning.
Completely unscrew tightening nut from 

pump’s head and remove assembling 

components: tightening nut, holding ring  

and pipe holder.
Assemble as shown in Fig. 6.

Insert hose into pipe holder until it reaches 

the bottom. Lock hose on pump’s head by 

screwing down the tightening nut.

Fig. 5. Pick

up v

alv
e & s

tr

ainer

 

Suction hose

Pipe holder

Threading nut

Pickup valve

Strainer

Fig. 4. Pick

up v

alv
e & s

tr

ainer o-ring ins

talla

tion
 

Содержание M3 SYSTEM

Страница 1: ...INFECTION CONTROL CONSULTANTS LLC OPERATING MANUAL The M3 System Delivery Module giccllc com Measure Manage Monitor...

Страница 2: ...INFECTION CONTROL CONSULTANTS LLC giccllc com PROVIDING A SAFE AND HEALTHY INDOOR ENVIRONMENT...

Страница 3: ...fety Guidelines 4 5 6 7 9 12 16 18 20 23 Purpose of Use and Safety Environmental Safety Transportation and Storage Installation Piping Connections Priming Troubleshooting Maintenance Warranty Table of...

Страница 4: ...rsion R1 General Safety Guidelines Operating installing or maintaining the unit in any way that is not covered in this manual could cause death serious personal injury or damage to the equipment This...

Страница 5: ...d from sun and water Avoid water splashes In emergencies the delivery module should be switched off immediately Disconnect the power cable from the power supply When installing always observe national...

Страница 6: ...of all waste Handle and dispose of the dosed product in compliance with applicable environmental regulations Clean up all spills in accordance with safety and environmental procedures Report all envi...

Страница 7: ...se or contact with unit Before returning the delivery module to the manufacturer for repair service drain the product from pump head and rinse Do not trash packaging Use it to return the delivery modu...

Страница 8: ...pulse min Maximum pressure bar PSI delivery PE suction PE Hoses cc per STROKE Environment temperature 5 50 C 23 113 F Solution temperature 0 50 C 32 122 F Transportation and storage temperature 10 50...

Страница 9: ...tenance tasks Failure to disconnect power can result in serious physical injury User health and safety equipment Use safety equipment according to the company regulations Use the following safety equi...

Страница 10: ...mp In a safe place and fixed flat surface wall to avoid vibration problems In an easily accessible place In vertical position Use only hoses compatible with product Only use fasteners of the proper si...

Страница 11: ...hereas the bottom of the unit has two screw locations Ensure that you are positioning the unit correctly with the air discharge hose at the top in vertical position When mounting the unit ensure the u...

Страница 12: ...on hose connection Suction hose should be as short as possible and installed in vertical position to avoid air bubbles when suctioning Completely unscrew tightening nut from pump s head and remove ass...

Страница 13: ...etely unscrew tightening nut from pump s head and remove assembly components tightening nut holding ring and pipe holder Assemble as shown in Fig 7 page 14 Insert hose into pipe holder until it reache...

Страница 14: ...ivery hose Threading nut Holding ring Pipe holder To delivery hose back pressure regulator To suction hose M3 System self venting pump head connection Refer to Fig 8 below for delivery and discharge h...

Страница 15: ...Notes Refer to Fig 9 and Fig 10 below for mounting instructions of the back pressure regulator and nozzle When connecting the piping ensure that the o ring has been properly installed to avoid leakage...

Страница 16: ...ecure delivery suction and discharge hose 2 Ensure the pickup valve is fully submersed and the bleed hose is also flowing back into pick up basin 3 Plug in the unit and turn on main power switch 4 Pre...

Страница 17: ...In this situation during priming mode rotate the adjustment pin counter clockwise until pin is level with black surface Once liquid starts to disperse from the nozzle start to screw the pin clockwise...

Страница 18: ...move the foot filter from liquid and hold the foot filter above the pump head level Run one cycle of purge with foot filter placed above the level of pump head Once complete place back into the liquid...

Страница 19: ...ve screws around base of the main unit Pull back cover until it s completed separated from main unit Remove board Completely disconnect wires from main board and replace it Reconnect wires to the main...

Страница 20: ...rvice and when handling chemicals Protective mask Protective gloves Safety goggles Ear plugs or ear muffs Further security device if necessary Always disconnect power before you perform any installati...

Страница 21: ...echanical seal Check electrical wiring Check for unusual noise and vibration noise allowed 73 dbA 5 dB Check the piping for leaks Check for corrosion on hoses This procedure should be carried out by a...

Страница 22: ...re and disconnect the discharge pipe from the discharge valve Path Away Anti Pathogenic Aerosol Solution or an approved alternative is the only fluid acceptable and approved for use in The M3 System D...

Страница 23: ...itted by applicable law or the Limited Warranty period provided herein whichever is longer GICC LLC shall not be liable to customer or anyone claiming under customer for any other obligations or liabi...

Страница 24: ...n supporting your local Recycle Environmental Program Working together we will form an active union to assure the world s invaluable resources are conserved INFECTION CONTROL CONSULTANTS LLC giccllc c...

Отзывы: