Global Power Technologies
START-UP AND OPERATION
05585 rev11 | Model 8550-SD
Page 15 of 53
Figure 8 – Power as a Function of Ambient Temperature
WARNING!
Do not operate the TEG above the curve on Figure 8. This may result in damage to
the Power Unit.
4.1.2
START-UP
Before starting up, connect a voltmeter across terminals 6 (+) and 4 (-) of TB-1. This will measure the
Power Unit voltage during start-up.
Connect the second voltmeter across Terminals 6 (+) and 7 (-) of TB-1. This will measure the Power
Unit current (1 mV = 1 Amp).
Follow these steps to start-up the Model 8550-SD TEG:
1.
Turn on the fuel supply to the TEG and observe the fuel pressure at the fuel pressure gauge.
Refer to the Start-up Data Sheet and compare the observed fuel pressure to the adjusted fuel
pressure as determined in Section 4.6.
If the pressure is lower, increase it by turning the screw on the pressure regulator clockwise
until it reaches the correct pressure.