INSTALLING INSTRUCTIONS
All Wiring procedures and connections shall be in
accordance with the national and local codes having
jurisdiction.
All wiring must be installed by a certified
electrician according to the local electrical
codes. The ceiling heater must be grounded in
accordance with all national and local building
codes.
To reduce the risk of fire, do not store or use
gasoline or other flammable vapors and
liquids in the vicinity of the heater.
CONTENTS
Part
Qty.
Description
1
2
3
4
5
6
7
8
9
2
2
1
2
1
1
2
1
1
Tilt adjustment knob
Rubber washer
Hex bolt M10 x 60mm L, zinc plated
Washer, 10mm, zinc plated
Spring washer
Nut
Expansion bolt
Wall hanger
Handle
Prior to installation:
·
Disconnect the main supply connection.
·
Supply cables shall be 8 AWG (8.3 mm2) copper wires.
·
The heater must be connected to individual branch circuit
protected by 40 Amp circuit breaker only.
·
Supply cables must be equipped with a dual pole circuit
breaker rating at least 240V 40A/pole as main cutoff
switch of power connection to the heater.
Tools/ Materials Needed (Not Included):
·
Regular Screwdriver Set
·
Spanner
·
Impact Drill with 12mm Drill Bit
Wall Mounted Installation
1.This heater should be installed at least 8 feet (2.4 m) from the
floor and no closer than 1 foot (0.3 m) from any adjacent
surfaces or walls. This minimum distance must be maintained.
2.Keep at least 4.5 inches (0.12m) from the back wall, regardless
of whether the wall mount bracket is used.
3.Mark the drill-hole positions in the wall or ceiling for the
mounting bracket.
4.Drill the required holes with diameter fitted to the anchor
provided for positioning the wall mount bracket.
5.Insert the anchors.
6.Attach the wall mount bracket to the wall or ceiling and secure
with mounting screws.
7.5 in
7.5 in
WALL MOUNT
CEILING MOUNT
7.Hook the unit to the wall mount bracket and let the unit hang
from the bracket.
8.Insert the screw through the mounting bracket and the heater handle.
Tighten the nut.
WALL MOUNT
CEILING MOUNT
9.Loosen the screw to remove the wiring compartment/connection cover
in the rear of the heater. There are three pigtail leads. Both Black (L1)
and Red one (L2) are for power connection; Green is for grounding
connection.
L1
L2
Black
Red
Green
remove
this cover
Horizontal Downflow Unit Heater
With Remote Control