Global Water
800-876-1172
•
globalw.com
- 4 -
III.
Tipping Bucket Installation
Tools and Materials Needed
You may need some of the following tools and materials to install the
RG200 Rain Gauge Tipping Bucket:
1.
Drill with 3/32" (2 mm) drill bit
2.
Medium Phillips Screwdriver
3.
3/16" (or 5 mm) Wrench
4.
Cable Clips or Weather-Resistant Cable Ties with screw holes or other
means for mounting
5.
Bubble Level
Precautions
a.
The tipping bucket requires a clear an unobstructed mounting location
to obtain accurate rainfall readings. It must also be mounted on a level
surface that is free of vibration. Once the tipping bucket is mounted
remove the housing cover by rotating it counter clockwise. Verify that
the tipping bucket is not held in the center position. If held in upright
gently press either end down against the stop to ensure proper
operation.
b.
To ensure that the surface is level, use a bubble level or pour water
into the T-shaped leveling trough in the base and observe the surface
of the water.
c.
Be sure there is an unobstructed path for water runoff from the drain
screens.
d.
Choose a location that is easily accessible for normal cleaning and is
distant from trees or other sources of heavy pollen or debris.