background image

 

Global Water 

800-876-1172 

 globalw.com 

 

 

- 4 - 

 

IV.

 

Specification: 

 

Power Supply: 

 

One 3.6 Volt, 2.4Ahr, AA Size Lithium Battery 

 

 

 

 

Global Water Part number 01-678 

or from mouser.com, part number 667-TL5903S 

 

 

 

 

 

Operating Temperature 

Industrial, -40ºC to +85ºC 

 

Pressure Sensor:   

0-200 psi gauge type sensor 

 

 

 

 

300 psi over-pressure 

 

 

 

 

Accuracy, +/- 1%, full scale 

 

 

 

 

Battery voltage monitor 

 

 

 

 

Analog Resolution:  12-Bit, 4096 Steps 

 

 

 

 

Sensor Warm-up Time:  0 Seconds (50mS Actual) 

 

Sample Modes: 

 

Fixed Interval:  Programmable from 1 Sec. to >1 Year 

 

 

 

 

High Speed:  10 Samples per second 

 

 

 

 

Logarithmic Sample Rate (Approximation) 

 

 

 

 

Exception (Log only on deviation from previous reading) 

 

Storage Capacity: 

81,759 Recordings of water pressure and battery 

voltage with date/time stamp 

 

 

 

 

 

Communication Ports: 

USB Type B 

Selectable Baud Rates:  Auto detect or fixed rates at 

9600, 19200, 28800, 38400, 57600, 115200 

57.6K Baud is recommended 

 

Thread Size:   

 

PL200-H-1:  2.5” BSP Male 

 

 

 

 

PL200-H-2:  2.5” NHT Female 

 

Spanner Wrench:   

Optional, 95-100mm 

 

 

 

 

Part Number 01-827 

 

 

 

 

 

Optional Adaptors:   

2.5” BSP Female to 2.5” NHT Female  

Part Number 01-826 

Call for other available adaptors 

 

Содержание PL200-H

Страница 1: ...1 PL200 H Hydrant Pressure Logger Global Water Instrumentation Inc 151 Graham Road P O Box 9010 College Station TX 77842 9010 T 800 876 1172 Int l 979 690 5560 Fax 979 690 0440 E mail globalw globalw...

Страница 2: ...e our technical staff will be happy to help Table of Contents I Checklist 3 II Inspection 3 III Warranty 3 IV Specification 4 V System Requirements 5 VI Accessing the USB Port 5 VII Software Installat...

Страница 3: ...defects in material and workmanship under normal use and service for a period of one year from date of shipment from factory Global Water s obligations under this warranty are limited to at Global Wa...

Страница 4: ...odes Fixed Interval Programmable from 1 Sec to 1 Year High Speed 10 Samples per second Logarithmic Sample Rate Approximation Exception Log only on deviation from previous reading Storage Capacity 81 7...

Страница 5: ...ut the Global Logger II icon on the desktop USB Driver Installation With the installation CD in the CDROM drive and DC power applied to the logger plug the USB cable into the data logger to open the A...

Страница 6: ...are Click No not at this time when asked if Windows Update can search for software Click Next 2 Do not let Windows automatically install the software Click Install from a specific location Click Next...

Страница 7: ...m will come to your computer 5 The first half of the installation is complete The Hardware Wizard must make two passes Click Finish 6 Two drivers might be required so the Hardware Wizard may repeat th...

Страница 8: ...Serial Port The COM setting following that will show the virtual COM port that has been automatically assigned to the driver As you will see in the following sections this COM port will be automatica...

Страница 9: ...the logger may be using a fixed rate mode try each connection speed separately especially 38400 which is required when using the Global Access software Direct connection is made through the USB port...

Страница 10: ...disconnect click on the Disconnect button This label on this button will change to Connect and clicking on it will return you to the connection screen as previously discussed Tool Bar The tool bar at...

Страница 11: ...se data to be read from the logger These include Sample Continuously Get Sample Sync Time and Setup whose functions are to be described later Interval This field displays the logging mode Fast indicat...

Страница 12: ...History This button starts the download of all the historical data stored in the logger memory Oldest data is collected first and Clicking Stop halts the process This function is described in detail...

Страница 13: ...itiate logging the Alarm 2 timer will halt logging at the next occurrence of the Alarm 2 time after the logger has been started by Alarm 1 If the Alarm 1 timer is not enabled the Alarm 2 timer will ha...

Страница 14: ...cussion of that subject and links to related topics underlined in blue Clicking on the link will bring up a new window with specific information on that topic In this case Sensor Warm up time in the G...

Страница 15: ...originally indicated At the top of the screen is shown the name assigned to the logger and the number of recordings that have been retrieved At the bottom of the screen are three buttons Pack Save to...

Страница 16: ...igital screen not being supported by the PL200H logger The first screen to appear is General Setup At the top of the setup screen is a toolbar with three options File Action and Help File The File opt...

Страница 17: ...will restore all of the analog digital and general setup information fields to default values Only the setup menus are changed the data logger must still be programmed with the new default values A wa...

Страница 18: ...e Leave this set to Auto Baud Rate Only change this to a fixed baud rate if planning to use this logger in a telemetry application such as using Global Water s Global Access radio modem software Once...

Страница 19: ...numeric field This logging exception applies to channel 1 only and the deviation is measured in Raw Data units where the approximate raw data range is from 0 65535 corresponding to 0 20mA To find the...

Страница 20: ...er or both alarms can be enabled Important These timers are a one time event the logger will not restart on the next occurrence of the Start timer unless the logger is reprogrammed with these settings...

Страница 21: ...output level before it is adjusted by the following calibration parameters These parameters are used to adjust the stored data for display and storage purposes only at the time the data is downloaded...

Страница 22: ...ved during the calibration process in this case a pressure of zero High Raw This is the raw data value as measured by the data logger that corresponds to the High EU value and is automatically set by...

Страница 23: ...ing the sensor can output In this example a pressure of 100 psi is used to calibrate the logger even though the sensor can measure up to 200 psi Click Next Place the sensor in the condition that will...

Страница 24: ...k to the main screen If no settings have changed Exit will occur immediately If settings have changed but not saved yet a message will appear that asks the user if they would like to save them now If...

Страница 25: ...e battery there are no user serviceable parts inside the PL200H Data Logger Global Water recommends checking the batteries every 6 to12 months or when the battery voltage monitor shows a low voltage c...

Страница 26: ...t it also consumes the most power Under normal conditions this feature will deplete the battery in about one week if left turned on You can increase the battery life significantly when using the high...

Страница 27: ...cable c Use the Device Manager to confirm that the driver is loaded and the correct virtual COM port is selected in the connection menu of the Global Logger software Check the Device Manager in your o...

Страница 28: ...specific problems relating to the product Be prepared to describe the problem you are experiencing including specific details of the application installation and any additional pertinent information I...

Отзывы: