Setup Menu 

 
To enter the setup menu, press and hold the MENU button for 2 
seconds.  Each press of the MENU button cycles through 1 of 4 
options,  Press BACK at any time to return to the main display mode.  
The 4 menu options are View data, Delete All Data, Set Velocity Units 
and Set Calibration Number; press SET to enter the setup screen for 
the current menu function. 
 

 
 
 
 
 
 
 
 

  View Data   

      Delete All 

         Set Units 

             Set Cal 

 
 
 
 

View Data 

 
From the View Data menu screen, press SET 
to review recorded data. 
 
The memory location is shown in the upper 
display and the data is shown in the lower 
larger display.  Use the UP and DOWN arrow 
buttons to change the memory location you  
wish to view.  Use the MODE button to select 
the average, minimum or maximum data value for 
the selected memory location.  The AVG, MIN or MAX icon is shown 
at the far right to indicate which data value is being displayed, AVG in 
the example shown.  Press the SET button to return to the menu 
display. 
 

Содержание FP111

Страница 1: ...r Instrumentation Visit Our Complete Online Catalog www globalw com Call 800 876 1172 7 30 AM to 4 PM Pacific Time International US 916 638 3429 FAX 916 638 3270 E mail globalw globalw com 11390 Amalg...

Страница 2: ...e a valuable asset for your application Should you require assistance our technical staff will be happy to help Table of Contents I Checklist Page 3 II Inspection 3 III Description 3 IV General Instru...

Страница 3: ...list to ensure that you have received everything needed to operate the Flow Probe III Description The Global Water Flow Probe is a rugged and highly accurate water velocity instrument for measuring fl...

Страница 4: ...usly stored data The flow probe computer is self contained and sealed It has an internal lithium battery that should last approximately 5 years depending on use The computer floats and is shock and wa...

Страница 5: ...updated once per second Pressing RESET before beginning a measurement is required for best accuracy e To determine flow from the velocity data measure or calculate the cross sectional area of your fl...

Страница 6: ...the flow through a series of flow surges c The water is not always moving in the same direction Even the smoothest water flow contains turbulence that causes the water to move in different directions...

Страница 7: ...ge minimum maximum velocities and a running average is started As long as the probe remains in the flow the averaging continues To stop averaging press the SAVE button in Save Data mode the averaging...

Страница 8: ...ow for the subsection Q V x A Once the flow of each subsection is obtained add all of the subsection flows to obtain the total stream flow c For the USGS 6 tens method the Flow Probe is placed at the...

Страница 9: ...to indicate different functions The SAVE button is used to save the average minimum and maximum velocity data to memory The RESET button causes the average minimum and maximum data to be set to the cu...

Страница 10: ...parameters to the memory location shown in the upper display and the computer returns to the main display mode automatically resetting the average minimum and maximum values The memory location is au...

Страница 11: ...enu function View Data Delete All Set Units Set Cal View Data From the View Data menu screen press SET to review recorded data The memory location is shown in the upper display and the data is shown i...

Страница 12: ...nd return to the menu screen Press SET to delete all data from memory Once deleted the data cannot be recovered Set Flow Units From the Set Units menu display Press SET to change the Flow Units The lo...

Страница 13: ...400 The calibration factor scales rotational speed to velocity in FT S only If the flow units are set to M S meters per second the calibration factor does not need to be changed Conversion between FT...

Страница 14: ...carbonate housing with polyester overlay Power Internal Lithium Approx 5 year life Non Replaceable Operating Temperature 20 to 70 C 4 to 158 F Non Freezing Storage Temperature 30 to 80 C 22 to 176 F V...

Страница 15: ...cycled at no charge c Cleaning Make sure the Turbo Prop turns freely before and after your measurements Blow on the prop in the direction of flow The prop should turn freely If not rinse the probe in...

Страница 16: ...te supplied with the flow probe It can also be obtained by contacting the Technical Support department at Global Water be ready to supply the serial number for the flow probe e If the display is blank...

Страница 17: ...e incurred during transit X Warranty a Global Water Instrumentation Inc warrants that its products are free from defects in material and workmanship under normal use and service for a period of one ye...

Страница 18: ...16 0 0811 0 66 0 5499 GPM x 1440 Gallons day GPD 0 17 0 0885 0 67 0 5594 0 18 0 0961 0 68 0 5687 0 19 0 1039 0 69 0 5780 0 20 0 1118 0 70 0 5872 0 21 0 1199 0 71 0 5964 0 22 0 1281 0 72 0 6054 0 23 0...

Страница 19: ...ng standard EN 61326 1 2006 Battery and Accumulators Directive 2006 66 EC Requirements regarding the proper handling and disposal of batteries and accumulators Due to the rugged conditions this produc...

Отзывы: