Chapter 6 — Service and Repair
Aliens Extermination System Manual
Page 36 of 56
040-0120-01 Rev. B 10/10/2006
connected). If the voltage is too high it will damage electronic components. If it is too low, the
game will not work properly.
5.
Be sure to connect the wires to the correct terminals. Refer to Figure 37 on page 52 for a
diagram.
Marquee Florescent Light Service
The marquee is lit by a florescent fixture. To gain access to the marquee fixture, remove the
three (3) wood screws and five (5) nuts with washers from the back of the marquee, and then
remove the marquee front with the artwork and clear plastic.
Replace the florescent tube with another 18" florescent tube.
To remove the fixture, disconnect the cabinet from AC power. Disconnect the AC power cord
from the fixture. Remove the two Phillips screws that secure the fixture to the cabinet and
remove the fixture. Replace the fixture with part # 49-1001-00.
Cold-Cathode Florescent Light Service
The cold-cathode florescent lighting is used for the "Mission Objective" instruction panel, and to
add dramatic lighting effects to the cabinet.
Note:
If both lights in a set fail, make sure the power connector is firmly attached to the power
inverter. Connect the lights to another power inverter to test them. Replace the power inverter if
faulty; it is held in place with Velcro and/or cable ties.
Refer to the table below if you need to replace a cold-cathode tube or inverter.
Light Location
Size & Qty
Changing Tube(s)
Inverter Location
Instruction Panel Two 6" White
Tubes
Remove the four (4) screws that
secure the instruction panel in
place.
Behind Instruction
Panel
Kick Panel
One 12" White
Tube
Remove the four (4) screws that
secure the clear plastic plate above
the kick panel.
Cabinet Floor
Area Below
Guns
Two 6" Blue
Tubes, One
Below Each Gun
Remove the four (4) screws that
secure the metal base plate below
the gun.
Behind Instruction
Panel
Speakers
One 12" Blue
Tube
Remove the four (4) Torx screws
that secure the speaker grill to
access the tubes. Remove the
back door to access the inverter.
Inside Cabinet on
Side Wall
Power Inverter
+12 VDC In from
DC Power Supply
2-Pin Connector Attached to Tube
Cold-Cathode Florescent Tubes
Figure 31.
Cold-Cathode Light Detail