LSK 1500/1550 User Manual, March 2021
45
© 2017 Global Payments Inc.
CONFIDENTIAL
Error Code
CDU Error Code Description and Diagnostics
1. Check note path for jam.
2. Check note for interference or blockage.
3. Check belt for proper engagement.
4. Replace CDU.
C0086
Note not arriving at count sensor (B) during dispensing
1. Check note path for jam.
2. Check belt for proper engagement.
3. Check note path structure for damage
4. Check reject gate for interference or damage.
5. Check belt and gear for proper engagement.
6. Measure sensor voltage <transmitter normal range of 1~3V>.
a. Normal range of 50~250 mV at empty
b. Normal range of 2~5 V when blocked
7. Replace sensor when the voltage is not in the normal range.
8. Replace Main B/D.
C009A
Note from 3rd CST not arriving at double timing sensor (H)
1. Check sensor (H) for blockage.
2. Check to ensure sensor is working properly.
3. Check cable from sensor to main B/D for damage or loose connector.
4. Measure sensor voltage <transmitter normal range of 1~3V>.
Normal range of 50~250 mV at empty
Normal range of 2~5 V when blocked
5. Replace Inlet sensor when the voltage is not in the normal range.
6. Replace Main B/D.
C009D
3rd cassette not detected
1. Check 3rd CST for its home position.
2. Check cable from 3rd feed module B/D to 3rd CST for damage or loose connector.
3. Check cable from 3rd feed module B/D to MAIN B/D for damage or loose connector.
4. Replace cassette.
5. Replace Main B/D.
C009F
3rd cassette failure to pick up
1. Check note inside cassette for interference by foreign object.
2. Check gears inside cassette for debris between gear teeth.
3. Check rollers inside cassette for damage.
4. Check push plate for interference.
5. Check cassette exit path for blockage.
6. Replace cassette.