18
Global Manufacturing, Inc
®
800.551.3569
TOLL FREE USA & CANADA
1801 East 22nd Street
501.374.7416
TEL
501.376.7147
FAX
Little Rock, AR 72206 USA
w w w. G l o b a l M a n u f a c t u r i n g . c o m
. Quick Exhaust Valve Installation:
GWE-Series Air Blasters come standard with a
Global G-Series Quick Exhaust Valve permanently
mounted. This patented valve was designed
specifically for use with Global Air Blasters. It
quickly evacuates air from the Air Blaster valve,
guaranteeing a full, powerful blast even when the
control valve is up to 100 feet from the Air Blaster.
This unique valve also ensures closure of the Air
Blaster valve immediately after the blast, which
helps to keep contaminants from entering the tank.
This feature of immediate valve closure, without
the use of a spring, is unique to Global GWE Air
Blasters. Other manufacturers use a spring which
can break, causing downtime. The ¾" air supply line
from the 3-Way normally open valve is connected
at the QEV inlet port.
Important!
The G-Series Quick Exhaust Valve is fitted with
two exhaust port bands. If "Replace Bands
Now!" is visible, the outer band is missing
and MUST be replaced immediately in
order for the valve to work properly.
1" G-Series Quick Exhaust Valve
Plant Air Inlet
"IN"
To Air Blaster
"AB"
Exhaust
If the QEV looks like
this image - replace
the two exhaust
bands immediately.
When the ‘outer band’ is destroyed, the ‘inside
band’ is exposed. This remaining band should
have the words "Replace Band Now" written
on it. Replace both bands. There must be two
exhaust bands on the QEV for it to operate
correctly. See page 37 for instructions.
There must be two bands on QEV
O u t e r B a n d
Illustration shows
band has been
damaged and needs
to be replaced.
I n n e r B a n d
"Replace Band Now"
is written on the
inner band.