Page | 5
All of Global Lift Corp’s Rotational Series Lifts are equipped with a sealed
24 volt battery that is rechargeable. Along with a charging unit, hand held
controller and control compartment. The 24 volt battery mounts right
above the control compartment and the battery simply snaps in. The
battery should be charged for 5-8 hours prior to the 1
st
use.
The unit is operated by the 4 button easy to use controls. Staff will use the
provided key to unlock the lift. The lock feature is located on the hand
controls or front of the control box. Insert the key provided and turn to
unlock the unit for use. (Avoid turning the key farther than 45 degrees as it
will damage the key) Once unlocked, the arrow pointing down will lower
the lift when depressed, the arrow that points up will raise the unit when
depressed and the bottom arrows will rotate the lift from left to right. If
you hear the low battery indicator tone “Do Not Use the Lift” remove the
battery from the unit and recharge the battery.
When the unit is not in use, remove the battery and place it on the
charger. The battery should never be left on the lift when not in use.
RECHARGING THE BATTERY:
Remove battery from the unit by unclipping from the control compartment.
Place the battery in the charging unit. When the battery is charging the
light will be illuminated, once fully charged the charge light will go off and
then the battery is ready for use in your Rotational Series pool lift.