Stainless Steel Drum Scale

Table5-2: use LB as primary unit: 

Calibration 

division value

Display division value in different weight unit that can be used

kg

g

lb

oz

lb:oz

0.0001lb

Not available

Not available

0.0001lb

0.002oz

Not available

0.001 lb

0.0005 kg

0.5g

0.001 lb

0.02oz

Not available

0.01 lb

0.005 kg

5g

0.01 lb

0.2oz

0.2 oz

0.1 lb

0.05 kg

50g

0.1 lb

2oz

2 oz

1 lb

0.5 kg

500g

1 lb

20oz

Not available

10 lb

5 kg

Not available

10 lb

Not available

Not available

0.0002 lb

0.0001 kg

0.1g

0.0002 lb

0.005 oz

Not available

0.002 lb

0.001 kg

1g

0.002 lb

0.05 oz

Not available

0.02 lb

0.01 kg

10g

0.02 lb

0.5 oz

0.5 oz

0.2 lb

0.1 kg

100g

0.2 lb

5 oz

Not available

2 lb

1 kg

Not available

2 lb

50 oz

Not available

20 lb

10 kg

Not available

20 lb

Not available

Not available

0.0005 lb

0.0002 kg

0.2g

0.0005 lb

0.01 oz

Not available

0.005 lb

0.002 kg

2g

0.005 lb

0.1 oz

0.1 oz

0.05 lb

0.02 kg

20g

0.05 lb

1 oz

1 oz

0.5 lb

0.2 kg

200g

0.5 lb

10 oz

Not available

5 lb

2 kg

Not available

5 lb

Not available

Not available

50 lb

20 kg

Not available

50 lb

Not available

Not available

ZERO

If the display does not show 0, and there is no an object on the platform, press the 

ZERO/ON/OFF

 key to zero the reading.   

Zero range: ±2% * full Capacity. 

The zero function is unavailable when the displayed reading is out of the zero range and 
the indicator will show the error message 

0

﹉﹉

﹉﹉

or 

0

﹍﹍

﹍﹍

, meaning the scale is over or 

under zero range

Setting a Tare Weight

1. Zero the scale as described above.

2. Place an empty container on the platform, press the 

TARE/PRESET

 key. The display

will return to zero, eliminating the weight of the contain

er. “

NET

 will be lit on the display.

3. Place the material or object to be weighed in the container. The net weight will be

displayed.

4. To exit tare mode, remove all weight from the scale. The display will show a negative

weight. Press the 

TARE/PRESET

 key to return the display to zero. 

Setting a Pre-Determined Tare Weight

1. Zero the scale as described above.

2. Press and hold the 

TARE/PRESET

 key until 

Pr.Tare

” is displayed, then the tare weight 

will    be displayed. The first digit and

 NET

 will flash in the display. 

3. Input the tare weight using the

keys. After inputting the tare weight, press 

the 

TARE/PRESET

key to confirm. “

NET

” will be lit in the display. 

User Manual

Содержание 412584

Страница 1: ...usuario Manuel de l utilisateur Customer Service US 1 800 645 2986 Servicio de atenci n al Cliente US 1 800 645 2986 Service la client le Canada 888 645 2986 Models 412584 Stainless Steel Drum Digita...

Страница 2: ...Setup Mode 9 Main menu 9 USER Submenu 10 5 OPERATIONS 15 Change working mode 15 Normal Weighing Mode 15 ZERO 16 Setting a Tare Weight 16 Setting a Pre Determined Tare Weight 16 Check Weighing Data Co...

Страница 3: ...ons table Allow the scale to acclimate to room temperature before using Allow sufficient warm up time Turn the scale on and allow up to 2 minutes for internal components to stabilize before weighing E...

Страница 4: ...it t lb kg D Di is sp pl la ay y 6 digit 7 segment 1 25mm LCD with backlight Z Ze er ro o R Ra an ng ge e Programmable zero range T Ta ar re e R Ra an ng ge e Full capacity S St ta ab bi il li iz za...

Страница 5: ...600mA adapter Indicator Manual U Un np pa ac ck ki in ng g a an nd d I In ns st ta al ll la at ti io on n Place the scale platform on a hard floor and level the feet Connect the indicator to the platf...

Страница 6: ...6 Stainless Steel Drum Scale 3 OVERVIEW OF CONTROLS AND FUNCTIONS Indicator Display Character Definitions User Manual...

Страница 7: ...ng mode Hold type is PEAK HOLD lb Measure unit is lb or lb oz oz Measure unit is oz or lb oz kg Measure unit is kg Measure unit is in percentage weighing mode Pcs Measure unit is pieces in counting mo...

Страница 8: ...hing mode 3 seconds Changes weighing unit of measure Counting or Percent mode 3 seconds Enters the submenu to input piece weight for counting or to enter reference weight for percent weighing Weighing...

Страница 9: ...main menu item then press the T TA AR RE E P PR RE ES SE ET T key to enter the item use key to select the submenu item to select a choice to set a number to confirm and save data and or to exit this m...

Страница 10: ...ed or request command received S ST TA AB BL LE E output after scale is stable N No ot te e use PRINT or CMD to output data the scale must be stable P Pr rt tc cm md d C CO ON NT T P PR RI IN NT T C C...

Страница 11: ...pt is STATUS N NO O N NO O B B L LI IN NE E N NO ON NE E How many blank lines after strings output NONE no blank line LINE1 2 3 4 there re 1 2 3 or 4 blank lines after strings used for paper feed forw...

Страница 12: ...Yes No enable disable output weight of 1 percentage Prompt is 1 REF WT N NO O N NO O C CO OU UN NT T Y YE ES S Yes No enable disable output counts Prompt is QUANTITY N NO O N NO O P PW WT T Y YE ES S...

Страница 13: ...il press HOLD key again to exit AVERAG Average HOLD mode in this mode if weight is over NLD RNG and its variation is less than HLD RNG the average data in AVG TIM will be frozen Press HOLD key or HLD...

Страница 14: ...time 0 not auto power off 1 255 auto power off after 1 255 minutes in this period no operation or no weight changing 5 5 O OF FF F M MD D O OF FF F Auto off mode OFF turn off instrument DSP TIM displa...

Страница 15: ...6 Power off the scale by pressing and holding the ZERO ON OFF key for 4 seconds Table5 1 use Kg as primary unit Calibration division value Display division value in different weight unit that can be...

Страница 16: ...t available 50 lb Not available Not available ZERO If the display does not show 0 and there is no an object on the platform press the ZERO ON OFF key to zero the reading Zero range 2 full Capacity The...

Страница 17: ...d move to the next step 4 Low will be displayed quickly the last Lo limit value will be displayed the default value is 000000 LO on the display will be lit Use the keys to input the lower limit of the...

Страница 18: ...quantity of the load that has been weighed 1 From normal weighing mode or percent weighing mode press and hold the P PR RI IN NT T F FU UN NC C key for 4 seconds Use the keys to select C CO OU UN NT T...

Страница 19: ...n after powering off The indicator can only save one piece weight Entering a new piece weight will automatically replace the old one C Ch he ec ck k C Co ou un nt ts s c co ou un nt ts s c co om mp pa...

Страница 20: ...play number if the scale is stable If the scale is not stable but the variation is less than U US SE ER R H HO OL LD D H HL LD D R RN NG G the scale will average data in U US SE ER R H HO OL LD D A AV...

Страница 21: ...eak HOLD mode the P PE EA AK K and H HO OL LD D announciator will be lit and for other HOLD modes the H HO OL LD D announciator will be lit When H HO OL LD D announciator is flashing the displayed num...

Страница 22: ...ror 1 calibration error 1 initial zero error 1 low battery 4 always 1 always 1 always 1 always 1 5 always 1 always 1 always 1 always 1 6 always 0 always 1 always 1 always 0 7 parity parity parity pari...

Страница 23: ...C CR R 58h 0dh Response power off the scale just like press down the off the scale viii Command all others Response Unrecognized command LF CR ETX b Summary of Command and Response C Co om mm ma an nd...

Страница 24: ...yte of string frame b Layout examples when U US SE ER R O OU UT T1 1 2 2 x xx xx xx x is set to Y YE ES S I In n w we ei ig gh hi in ng g m mo od de e SCALE ID GROSS TARE NET ACC N TOTAL DATE TIME A D...

Страница 25: ...ame as W above K K 4b Switch to and send metric weight Same as W above others Un known commands STX Status Byte CR 9 Communication Details when U US SE ER R C CO OM M1 1 2 2 L LA AY YO OU UT T is set...

Страница 26: ...ponse Command Response ASCII HEX W CR 57 0D Returns decimal lb kg or oz weight units and status LF pxxx xxUU CR hh ETX Returns ounces weight with units plus scale status LF p00xxxxxOZ CR hh ETX Scale...

Страница 27: ...the scale and press the TARE PRESET key to confirm the Z ZE ER RO O will flash when it is in the catching zero point state After receiving reasonable data it will automatically continue to step 8 Lin...

Страница 28: ...sed on C CA AL L P P2 2 onto the scale The next operation steps are the same as explained in step b g When the stable and reasonable data corresponding to the standard weight has been received the ind...

Страница 29: ...29 Stainless Steel Drum Scale TABLE6 1 Location Code for different elevation and latitude User Manual...

Страница 30: ...e display Format is xx xx xx hh mm ss 24h format 3 Press and hold the UNIT DATA key for more than 4 seconds to enter modification time mode Using keys to modify current time If inactivity exceeds 5 se...

Страница 31: ...ght reading below Power On Zero limit 1 Install platform on the scale 2 Check whether an object stuck between the load cell and scale base if yes remove the object 3 Perform zero calibration 1 Weight...

Страница 32: ...uring units missed CONFIG parameters are not correctly set Re set CONFIG parameters per the Technical Manual Incorrect counting result or percent weighing result when using SPL to enter a piece weight...

Страница 33: ...nless Steel Drum Scale 1 10 0 R Re ep pl la ac ce em me en nt t p pa ar rt t P Pa ar rt t N Nu um mb be er r D De es sc cr ri ip pt ti io on n 318529 AC adapter 9V 600mA 412587 Display Indicator User...

Отзывы: