Preforming a Forced Reset

Error Logs

Software Version

Error Codes

If Standard Reset (page 6) does not initiate a reset, preform a Forced Reset.

Shows the number of times each error has occurred since start-up or last reset.

Hard stop

Back off

Soft stop

Waiting for button

Waiting for button release

Motor lost

7 Overcurrent

Overheating: Thermometer flashing, wait 10 minutes 

 

for motor cooling.

Low voltage: (under 16vdc)

10 

High voltage: (over 40vdc)

11 

Out of sync / legs too far apart

12 

Destination above upper limit

13 

Destination below lower limit

14 

Internal error

15 

Collision detected by CDS

16 

Wrong number of motors connected

17 

Destination above upper motor limit

18 

Destination below lower motor limit

19  

Slave lost / Disconnected

20  

Motor not moving

Display Software Version

Select by pressing the M button.

Select by pressing the M button.

Select by pressing the M button.

Return to Menu by pressing the M button.

Activate Reset / Homing by pressuring the 
Down button.

Navigate with the Up or Down button to 
the error number you want to view.

Software Version will appear on the 
display.

Software Version Displayed

Return to Menu by pressing the M button.

Default error code example

Error code 8, flashing 
thermometer

Press and hold M button for at least 8 
seconds...

... until three dashes are displayed.

Press and hold M button for at least 8 
seconds...

... until three dashes are displayed.

Press and hold M button for at least 8 
seconds...

... until three dashes are displayed.

M

M

M

M

M

M

M

M

Release the M button.

Release the M button.

After 1 second of inactivity, the number 
of times that error has occured will 
display.

Release the M button.

Use the Up or Down button to navigate 
to RES (Reset).

Use the Up or Down button to navigate 
to Err.

Use the Up or Down button to navigate 
to SOF (Software Version).

Release

Release

Number of times 
the error occured 
displayed

Release

RES

123

SOF

Содержание Free Fit Flow Ease Handset

Страница 1: ...s on the Internet at globalcontract com 416 739 5000 ISO 9001 2008 OHSAS 18001 2007 ISO 14001 2004 Global Contract Inc 565 Petrolia Road North York Ontario M3J 2X8 2019 Free Fit Flow Visual Handset User manual ...

Страница 2: ...ing M Installation Connect Button Guide Symbol Guide Start Up Attach the handset to the underside of the table top using the two provides screws If the worksurface thickness is less than 18mm 3 4 use shorter screws not provided Explanation of the display Connect the handset cable to one of the columns connetor ports The second port on the handset can be used to connect other devices Adjust the tab...

Страница 3: ...the desk to the quick memory position the desk will stop at the preset height Release the button immediately press the Up or Down but ton to store the current height as a quick memory position to the selected button Press the M button to save current height Press and hold the same button as previ ously to bypass the desks preset height Press the M button and release Hold the M button for at least ...

Страница 4: ...o Menu by press ing the M button Select value and return to Menu by press ing the M button Press and hold M button for at least 8 seconds until three dashes are displayed Press and hold M button for at least 8 seconds until three dashes are displayed Press and hold M button for at least 8 seconds until three dashes are displayed Calibrate Upper Limit by using the Up or Down buttons Calibrate Upper...

Страница 5: ...ressing the M button Select by pressing the M button Select by pressing the M button Return to Menu by pressing the M button Activate Reset Homing by pressuring the Down button Navigate with the Up or Down button to the error number you want to view Software Version will appear on the display Software Version Displayed Return to Menu by pressing the M button Default error code example Error code 8...

Страница 6: ...enu by pressing the M button navigate with the Up or Down button to see the oldest Firmware Version Software Version Displayed Press and hold M button for at least 8 seconds until three dashes are displayed M M M Release the M button Use the Up or Down button to navigate to Act Actuator Columns Release USER GUIDE ...

Страница 7: ... Page globalcontract com 7 March 2019 GLOBALContract USER GUIDE ...

Страница 8: ...ALGARY SHOWROOM 302 8 Avenue SE Calgary AB T2G 2M3 TEL 403 250 7770 WINNIPEG SHOWROOM 220 111 Lombard Avenue Winnipeg MB R3B 0T4 TEL 204 925 3350 OTTAWA SHOWROOM 251 Laurier Avenue West 4th Floor Ottawa ON K1P 5T6 MONTREAL SHOWROOM 980 St Antoine Street Ouest Montreal Bureau 200 QC H3C 1A8 TEL 514 866 4331 HALIFAX SHOWROOM 1061 Marginal Road Suite 120 Halifax Nova Scotia B3H 4P7 TEL 902 422 7434 Q...

Отзывы: