background image

10

107299

PROPANE/LP GAS HEATER

CHECKING GAS
CONNECTIONS

 WARNING: Test all gas pip-

ing and connections for leaks
after installation or servicing.
Correct all leaks at once.

 WARNING: Never use an open

flame to check for a leak. Apply a
mixture of liquid soap and water
to all joints. Bubbles forming
show a leak. Correct all leaks at
once.

 CAUTION: Make sure exter-

nal regulator has been installed
between propane/LP supply and
heater. See guidelines under 

Con-

necting to Gas Supply, page 9.

Pressure Testing Gas Supply
Piping System

Test Pressures In Excess Of 1/2 PSIG
(3.5 kPa)

1.

Disconnect appliance with its appliance
main gas valve (control valve) and equip-
ment shutoff valve from gas supply pip-
ing system. Pressures in excess of 1/2
psig will damage heater regulator.

2.

Cap off open end of gas pipe where
equipment shutoff valve was connected.

3.

Pressurize supply piping system by ei-
ther using compressed air or opening
propane/LP supply tank valve.

4.

Check all joints of gas supply piping
system. Apply mixture of liquid soap
and water to gas joints. Bubbles form-
ing show a leak.

5.

Correct all leaks at once.

6.

Reconnect heater and equipment
shutoff valve to gas supply. Check re-
connected fittings for leaks.

Test Pressures Equal To or Less Than
1/2 PSIG (3.5 kPa)

1.

Close equipment shutoff valve (see Fig-
ure 15).

2.

Pressurize supply piping system by ei-
ther using compressed air or opening
propane/LP supply tank valve.

3.

Check all joints from propane/LP sup-
ply tank to equipment shutoff valve (see
Figure 16). Apply mixture of liquid
soap and water to gas joints. Bubbles
forming show a leak.

4.

Correct all leaks at once.

Figure 15 - Equipment Shutoff Valve

Open

Closed

Equipment
Shutoff Valve

Figure 16 - Checking Gas Joints

INSTALLATION

Continued

Pressure Testing Heater Gas
Connections

1.

Open equipment shutoff valve (see Fig-
ure 15).

2.

Open propane/LP supply tank valve.

3.

Make sure control knob of heater is in
the OFF position.

4.

Check all joints from equipment shutoff
valve to control valve (see Figure 16).
Apply mixture of liquid soap and wa-
ter to gas joints. Bubbles forming show
a leak.

5.

Correct all leaks at once.

6.

Light heater (see Operating Heater,
page 11 for non-thermostat models or
pages 12 and 13 for thermostat model).
Check all other internal joints for leaks.

7.

Turn off heater (see To Turn Off Gas
To Appliance
, page 11 for non-thermo-
stat models or page 12 for thermostat
model).

8.

Replace front panel.

Propane/LP
Supply Tank

Control
Valve
Location

Equipment
Shutoff Valve

Содержание FB-10BA

Страница 1: ...llationandservicemustbeperformedby a qualified installer service agency or the gas supplier WARNING Thisisanunvented gas firedheater Itusesair oxy gen from the room in which it is installed Provisions for ad equate combustion and venti lation air must be provided Refer to Air For Combustion and Ventilation on page 4 of this manual WARNING Improper installa tion adjustment alteration service or mai...

Страница 2: ...pplianceareaclearand free from combustible materials gasoline and other flammable vapors and liquids 1 This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases 2 Do not place propane LP supply tank s inside any structure Locate propane LP supply tank s outdoors 3 If you smell gas shut off gas supply do not try to l...

Страница 3: ...rton 2 Remove all protective packaging ap plied to heater for shipment 3 Check heater for any shipping damage If heater is damaged promptly inform dealer where you bought heater PRODUCT FEATURES SAFETY DEVICE This heater has a pilot with an Oxygen DepletionSensing ODS safetyshutoffsys tem The ODS pilot is a required feature for vent freeroomheaters TheODS pilotshuts off the heater if there is not ...

Страница 4: ...d ventilation However in buildings of unusually tight construction you must provide additional fresh air Unusually tight construction is de fined as construction where a walls and ceilings exposed to the outside atmosphere have a con tinuous water vapor retarder with a rating of one perm 6 x 10 11 kg per pa sec m2 or less with open ings gasketed or sealed and b weather stripping has been added on ...

Страница 5: ... all fuel burning appliances in the space Vent free heater ______________ Btu Hr Gas water heater ______________ Btu Hr Gas furnace ______________ Btu Hr Vented gas heater ______________ Btu Hr Gas fireplace logs ______________ Btu Hr Other gas appliances ______________ Btu Hr Total ______________ Btu Hr Do not include direct vent gas appliances Direct vent draws combustion air from the outdoors a...

Страница 6: ...tethepowervent VENTILATION AIR Ventilation Air From Inside Building Thisfreshairwouldcomefromanadjoining unconfined space When ventilating to an adjoining unconfined space you must pro vide two permanent openings one within 12 of the ceiling and one within 12 of the floor on the wall connecting the two spaces see options 1 and 2 Figure 2 You can also remove door into adjoining room see op tion 3 F...

Страница 7: ...e cloth ing orotherflammableobjects arelessthan36inchesfromthe front top or sides of the heater as a fireplace insert in high traffic areas in windy or drafty areas CAUTION If you install the heater in a home garage heater pilot and burner must be at least 18 inches above floor locateheaterwheremovingve hicle will not hit it CAUTION Thisheatercreates warmaircurrents Thesecurrents moveheattowallsur...

Страница 8: ... walls wall areas between studs or to solid walls concrete or masonry Decidewhichmethodbettersuitsyourneeds Eithermethodwillprovideasecureholdfor the mounting bracket Removing Front Panel Of Heater 1 Remove two screws near bottom cor ners of front panel 2 Liftstraightupongrillguarduntilitstops Grill guard will slide up about 1 4 3 Pull bottom of front panel forward then down 4 Remove cardboard pac...

Страница 9: ...gas to the appliance Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves CAUTION Neverconnectheater directly to the propane LP supply This heater requires an external regulator not supplied Install the external regulator between the heater and propane LP supply CAUTION Use only new black...

Страница 10: ...utoff valve to gas supply Check re connected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Fig ure 15 2 Pressurize supply piping system by ei ther using compressed air or opening propane LP supply tank valve 3 Check all joints from propane LP sup ply tank to equipment shutoff valve see Figure 16 Apply mixture of liquid soap and water t...

Страница 11: ...ion MANUAL LIGHTING PROCEDURE OPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTING A This appliance has a pilot which must be lighted by hand When lighting the pilot follow these instructions exactly B BEFORE LIGHTING smell all around the appliance area for gas Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not t...

Страница 12: ...first time after hook ing up to gas supply If so you may need to press in control knob for 30 seconds This will allow air to bleed from the gas system 6 Release downward pressure on con trol knob and turn clockwise to OFF position 7 Press in control knob and turn coun terclockwise past IGN to PILOT see Figure 19 This will cause the piezo ignitor to spark and light the pilot gas Keep control knob d...

Страница 13: ...lights 3 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob Follow steps 8 and 9 under Lighting Instruc tions page 12 OPERATING HEATER Continued CLEANING AND MAINTENANCE WARNING Turn off heater and let cool before cleaning CAUTION You must keep control areas burner and circu lating air passageways of heater clean Inspect these areas of heater bef...

Страница 14: ...tor button is pressed there is no spark at ODS pilot When ignitor button is pressed there is spark at ODS pilot but no ignition ODS pilot lights but flame goes out when control knob is released REMEDY 1 Replace ignitor 2 Replace ignitor 3 Reconnect ignitor cable 4 Free ignitor cable if pinched by any metal or tubing Keep ignitor cable dry 5 Replace ignitor cable 6 Replace control valve ignitor is ...

Страница 15: ...few hours of operation 1 Turn control knob to LOW position and let warm up for a minute 2 Operate burner until air is removed from line Have gas checked by local propane LP gas company 3 Observe minimum installation clear ances see Figure 4 page 7 4 Clean burner see Cleaning and Mainte nance page 13 or replace burner orifice 1 This is common with most heaters If noise is excessive contact qualifie...

Страница 16: ... 2 Contact local propane LP gas company 3 Clean ODS pilot see Cleaning and Maintenance page 13 1 Locate and correct all leaks see Check ing Gas Connections page 10 2 Replace control valve 1 Take apart gas tubing and remove for eign matter 2 Locate and correct all leaks see Check ing Gas Connections page 10 1 Refer to Fresh Air for Combustion and Ventilation requirements page 4 POSSIBLE CAUSE 1 Hea...

Страница 17: ...d on the back page of this manual Send a check for 5 00 payable to DESA International You may have further questions about in stallation operation or troubleshooting If so contact DESA International s Techni cal Service Department at 1 800 323 5190 You can also visit DESA International s technical service web site at www desatech com TECHNICAL SERVICE SERVICE HINTS When Gas Pressure is Too Low pil...

Страница 18: ...ase date Usually we will ask you to return the defec tive part to the factory REPLACEMENT PARTS EQUIPMENT SHUTOFF VALVE GA5010 Equipmentshutoffvalvewith1 8 NPTtap ACCESSORY Purchase this heater accessory from your local dealer If they cannot supply this ac cessory either contact your nearest Parts Central see page 19 or call DESA International s Parts Department at 1 800 972 7879 for referral info...

Страница 19: ...ay W Long Branch NJ 07764 1542 732 870 8809 1 800 755 8809 www njplaza com ecep Tarantin Tank Co P O Box 6129 Freehold NJ 07728 6129 908 780 9340 1 800 922 0724 www tarantin com Heater Fireplace Store 58 Halbe Lane Cape May Court NJ 08210 1110 609 390 9774 Parts Department Dayton Hardware P O Box 275 North Dayton Station Dayton OH 45404 0275 All States 937 258 3721 OH 1 800 762 3426 Halco Enterpri...

Страница 20: ... 107299 PROPANE LP GAS HEATER FB 10BA 28 2 28 1 ILLUSTRATED PARTS LIST ODS Pilot Assembly 7 7 32 2 3 19 17 8 9 22 32 31 26 30 27 23 18 28 29 10 21 20 18 30 25 24 22 17 16 13 1 14 15 7 11 12 33 4 5 7 6 7 7 ...

Страница 21: ...er 2 15 L98806 01 Self Tapping Screw 2 16 L98915 02 Pressure Tap Assembly 1 17 L98115 04 Main Inlet Tube Assembly 1 18 L98123 10 ODS Line Assembly 1 19 L98127 02 Lower Gas Outlet Tube Assembly 1 20 L98128 02 Medium Gas Outlet Tube Assembly 1 21 L99516 01 Leveled T Connector 1 22 L98126 04 Burner Inlet Tube Assembly 1 23 L98506 03 Burner 1 24 L98507 02 Burner Connector 1 25 L98508 06 Injector 1 26 ...

Страница 22: ...22 107299 PROPANE LP GAS HEATER FB 60BA 25 2 25 1 ILLUSTRATED PARTS LIST ODS Pilot Assembly 7 7 29 2 3 19 17 8 9 29 28 23 27 24 20 18 25 26 10 18 9 27 22 21 19 17 16 13 1 14 15 7 11 12 30 4 5 7 6 7 7 ...

Страница 23: ...ntrol Knob 1 13 L98029 04 Pressure Regulator 1 14 L98801 01 Washer 2 15 L98806 01 Self Tapping Screw 2 16 L98915 02 Pressure Tap Assembly 1 17 L98115 04 Main Inlet Tube Assembly 1 18 L98123 10 ODS Line Assembly 1 19 L98126 05 Burner Inlet Tube Assembly 1 20 L98506 04 Burner 1 21 L98507 02 Burner Connector 1 22 L98508 12 Injector 1 23 L98504 02 Left Burner Support Bracket 1 24 L98505 02 Right Burne...

Страница 24: ...24 107299 PROPANE LP GAS HEATER FBS 10BB 27 2 27 1 ILLUSTRATED PARTS LIST ODS Pilot Assembly 7 7 14 2 3 20 19 14 12 25 8 11 11 13 10 26 22 20 27 28 13 10 24 23 21 19 21 15 1 16 17 7 18 4 5 7 6 7 7 9 ...

Страница 25: ... 01 Nut 2 11 L98084 01 Screws 2 12 L98010 08 Grill 1 13 L98411 01 Ignitor Line 1 14 L98011 01 Grill Fastener 2 15 L99029 08 Pressure Regulator 1 16 L98801 01 Washer 2 17 L98806 01 Self Tapping Screw 2 18 L98085 02 Mounting Bracket 1 19 L98115 07 Main Inlet Tube Assembly 1 20 L98123 11 ODS Line Assembly 1 21 L98126 07 Burner Inlet Tube Assembly 1 22 L98506 03 Burner 1 23 L98507 01 Burner Connector ...

Страница 26: ...to parts that are not in original condition because of normal wear and tear or parts that fail or become damaged as a result of misuse accidents lack of proper maintenance or defects caused by improper installation Travel diagnostic cost labor transportation and any and all such other costs related to repairing a defective heater will be the responsibility of the owner TO THE FULL EXTENT ALLOWED B...

Отзывы: