background image

Rev. 0-401

3

Model GLI-9143 Portable D.O. Meter

The dissolved oxygen probe has a mem-
brane covering the polarographic sensor
elements and a built-in thermistor for tem-
perature measurement and compensation.
The thin permeable membrane isolates the
sensor elements from the testing solution, but
allows oxygen to enter. When a voltage is
applied across the sensor, oxygen that
passes through the membrane causes a cur-
rent to flow from which the oxygen
concentration is determined.

FUNCTIONAL DESCRIPTION -- PROBE

1) D.O. 

Probe

2) Protective 

Cap

3)  Watertight Shielded Cable

4)  Polypropylene Probe Body

5) Temperature 

Sensor

6) O-ring 

Seal

7)  Silver Chloride Anode (sensor element)

8)  Platinum Cathode (sensor element)

9)  Oxygen-permeable Teflon Membrane

10) Protective Cap

FUNCTIONAL DESCRIPTION -- METER

1)

Battery compartment

2)

Probe connector

3)

Liquid crystal display

4)

ON/OFF button

5)

CAL button (to enter or exit calibration
mode)

6)

FACTOR button (to select altitude F1
and salinity F2)

7)

UP and DOWN arrow keys (to select F1
and F2 levels)

8)

HOLD key (to freeze displayed value)

9)

RANGE button (to select ppm or % of
saturation)

10) Power jack for 12VDC adapter

19) LOW BAT indicator

20) SAMPLE indicator (to indicate the meas-

urement mode)

21) F1 indicator (altitude factor)

22) F2 indicator (salinity factor)

23) % or ppm mode indicator

24) Temperature (and factor) display

Содержание GLI-9143

Страница 1: ...Manual No 9143 Revision 0 401 MODEL GLI 9143 HAND HELD PORTABLE DISSOLVED OXYGEN METER ...

Страница 2: ... material until you are sure that the instrument func tions correctly All defective items must be returned in their original packaging together with the supplied accessories GENERAL DESCRIPTION The GLI 9143 is a water resistant micro processor based auto calibration Dissolved Oxygen meter with automatic temperature compensation ATC It has been developed for dissolved oxygen and temperature measure...

Страница 3: ... Polypropylene Probe Body 5 Temperature Sensor 6 O ring Seal 7 Silver Chloride Anode sensor element 8 Platinum Cathode sensor element 9 Oxygen permeable Teflon Membrane 10 Protective Cap FUNCTIONAL DESCRIPTION METER 1 Battery compartment 2 Probe connector 3 Liquid crystal display 4 ON OFF button 5 CAL button to enter or exit calibration mode 6 FACTOR button to select altitude F1 and salinity F2 7 ...

Страница 4: ...76407A P supplied with the meter and make sure that the rubber O ring sits properly inside the membrane cap 4 Rinse the mem brane cap with electrolyte while shaking it gently Refill with clean electrolyte 5 Gently tap the sides of the mem brane cap with your finger tip to ensure that no air bubbles remain trapped To avoid damaging the membrane do not tap the membrane cap directly on the bottom 6 W...

Страница 5: ...ss FACTOR and ensure F1 and F2 are set to the appropriate altitude and salinity values see ALTITUDE and SALINITY COMPENSATION NOTE The instrument must be calibrated whenever the probe membrane or the electrolyte is changed To exit the calibration mode during calibration press CAL The display may be switched from readings in saturation to ppm without re calibration by simply pressing RANGE MEASUREM...

Страница 6: ...y will show the measured temperature in degrees Celsius Allow the probe to reach thermal equilibrium with the sample before taking any measure ment The greater the difference between the ambient temperature and the temperature of the sample the longer it will take the probe to equilibrate to the sample ALTITUDE COMPENSATION Press FACTOR and F1 will be displayed Use the UP and the DOWN keys to set ...

Страница 7: ...shed or stained which could be due to contact with certain gases or extended use with a loose or damaged mem brane the cathode should be cleaned 1 Use a clean lint free cardboard or cloth and rub the cathode very gently side to side 4 5 times This will be enough to polish and remove any stains without damaging the platinum tip 2 Rinse the probe with deionized or dis tilled water 3 Install a new me...

Страница 8: ...Meter to be free from defects in material or workmanship for a period of one year 12 months from the date of shipment of this product from our facility The GLI 76407 4 or GLI 76407 10 Dissolved Oxygen Sensor is warranted for a period of 6 months A war ranty claim will not be honored if defects are not reported within the warranty period or if GLI International determines that defects or damages ar...

Отзывы: