Page 8

Battery Instructions

This  system  will  accommodate  both  PHCC  Pro
Series  B-2200  wet  cell  as  well  as  the  B12-90
maintenance free (AGM) batteries.  To double the
runtime of the backup system, two of the same
model batteries can be connected together. The
batteries  should  be  of  similar  age.    Connecting
an old and new battery together will not charge
properly. Specific connection instructions will be
explained on page 10.

• The  use  of  automotive  batteries  is  NOT

recommended.    Automotive  batteries  are
not designed for this application.  They will
only run the pump for a short time and will
have a shorter life than a standby battery.

• The battery fluid sensor is designed to fit

the  Pro  Series  Standby  batteries.
Measuring  the  battery  fluid  is  one  of  the
most  important  features  of  the  system,
since  about  80%  of  backup  sump  pump
failures are the result of a battery that has
dried out.

• The internal construction of some wet cell

batteries may not be compatible with this
system.  Glentronics can not guarantee the
compatibility of other brands of batteries.
The  use  of  a  PHCC  Pro  Series  B-2200  or
B12-90 battery is HIGHLY recommended.

DO NOT insert the fluid sensor into any
battery except a Pro Series Standby battery.
DO NOT drill a hole in another brand of
battery to accommodate the fluid sensor.  
DO NOT use the enclosed battery cap on any
battery except a Pro Series battery.  DO NOT
drill a hole in the cap of another brand of
battery to accommodate the fluid sensor.
Batteries emit explosive gases which can
cause serious injury or death.

PREPARING THE PRO SERIES

STANDBY BATTERY

The Pro Series Standby batteries are shipped dry
(without  acid)  so  they  never  lose  power  before

you  take  them  home.    A  battery  is  activated
when  the  acid  is  added,  and  then  it  slowly
begins to deteriorate as it ages.  By adding the
acid just before use, the battery will always be
fresh.  Use 1.265 specific gravity battery acid to
fill  the  battery.    It  is  available  where  you
purchased the battery.

Contains sulfuric acid.  Wear eye and
clothing protection.  If battery acid contacts
skin or clothing, wash immediately with
soap and water.  If acid enters eyes, flush
with water for 15 minutes, and get prompt
medical attention.  Review the safety
instructions on page 1.

PRO SERIES BATTERIES COME IN TWO
CONFIGURATIONS.  THE TOPS OF THE BATTERIES
LOOK DIFFERENT, AND THE DIRECTIONS FOR
FILLING THE BATTERIES AND CONNECTING THE
FLUID SENSOR WILL VARY SLIGHTLY.  IF THE TOP
OF YOUR BATTERY LOOKS LIKE PHOTO A, FOLLOW
THE INSTRUCTIONS ON THIS PAGE.  IF THE TOP
OF YOUR BATTERY LOOKS LIKE PHOTO B ON PAGE
9, FOLLOW THE INSTRUCTIONS ON PAGE 9.

TO FILL THE BATTERY

1. Remove  the  cover  of  the  battery  box  by

pushing in the tabs on the front and back of
the box and lifting up.

2. Place the battery box on the floor.  Place the

dry  (unfilled)  battery  into  the  battery  box.
Remove the foil seal on the top of the battery.

3. Carefully push in the perforated tab at the top

of  the  acid  pack.    Lift  up  the  large  tab  and
pull out the dispensing hose.  Hold the hose
upright above the pack and squeeze the hose
forcing all the acid back into the pack.

4. Position the acid pack and battery as shown

at  the  right.    Pinch  the  end  of  the  hose
together and cut off the tip.  Insert the end
of the hose into each cell.  Control the flow
by  pinching  the  hose  with  thumb  and
forefinger.  

Fill each cell of the battery to a

level  just  covering  the  battery  plates,  and
then go back and top off each cell equally.
It  is  important  to  have  all  the  cells  filled
equally or  the  battery  will  not  operate
properly.

The acid should reach a level about

¼”  below  the  cap  ring  as  shown  in  the
diagram  below.    DO  NOT  OVERFILL  THE
BATTERY.  (Diagram E)

A  newly  filled  battery  will  sometimes  require
additional  acid  after  about  20  minutes.    Re-
examine the fill level, and add additional acid if
necessary.    The  battery  acid  may  bubble  at  this
time and give off a sulfur-like smell, but this is
normal.  After the battery has been filled, screw
the six (6) caps securely on the top of the battery.

The battery will be charged 70-80% 30 minutes
after  adding  the  acid.    The  system  will  then
finish charging the battery.  During this time the
alarm may sound. 

When you fill the battery for the FIRST time,
it will be the ONLY time you add acid to the
battery.  In the future, when the fluid level is
low,  add  distilled  water  to  the  cells.    NEVER
add more acid.

This  backup  system  will  also  accommodate  a
maintenance-free  battery,  eliminating  the  need
to fill the battery.  Slide the switch on the front
of  the  controller  panel  to  the  type  of  battery
being used with the system.  The fluid sensor is
not  needed  when  using  maintenance-free
batteries.  However, you 

MUST

attach the fluid

sensor  to  the  positive  post  of  the  battery  to
silence the fluid alarm.

CAUTION

!

DANGER

!

DANGER/POISON

CAUTION

2nd LEVEL

1st LEVEL

PLATES

CELL WALL

1  

 

  1st LEVEL, COVER THE PLATES

 

 

 

 

 

 

 

        THE BOTTOM OF THE CAP RINGS

BATTERY  TERMINALS

BATTERY CAP RINGS

CROSS SECTION OF BATTERY

1. Fill to 1st level, cover

the plates

2. Then fill to 2nd level,

just below the bottom
of the cap rings

Diagram E

Do not throw an
old battery in the
trash.  Take it to a
service station or
recycling center.

1

4

3

BATTERY A

2

Содержание PHCC 2400 Pro Series

Страница 1: ...ction to existing discharge for narrow sumps 7 Battery Instructions 8 9 Control Unit Connections Positioning the float switch 9 Connecting the pump 9 Installing the battery fluid sensor 10 Connecting...

Страница 2: ...ntronics Inc 645 Heathrow Drive Lincolnshire IL 60069 4205 BATTERY PREPARATION Sulfuric acid can cause blindness or severe burns Avoid contact with skin eyes or clothing In the event of an accident fl...

Страница 3: ...battery with this system It will not run the pump as long as the Pro Series 2200 or B12 90 battery The internal construction of some wet cell batteries may not be compatible with this system Glentron...

Страница 4: ...e main AC pump Try to fit the backup pump on the floor of the sump first Make sure there is enough room so the backup pump and the main pump do not touch each other Select the installation method that...

Страница 5: ...ia the shortest path with the fewest turns More turns will reduce the pumping capacity The pipe section exiting the building should be on a downward slope so that the water in the pipe will exit outsi...

Страница 6: ...lled at this time Cut the discharge pipe approximately one 1 foot above the floor Install a check valve on the top of the pipe and tighten the bottom hose clamp Now prime and cement a small piece of 1...

Страница 7: ...he details of each installation will vary Using sound plumbing practices route the discharge pipe to an exterior wall via the shortest path with the fewest turns More turns will reduce the pumping cap...

Страница 8: ...attached to the Pro Series pump Make sure it is installed with the arrow pointing up or it will not prevent the backflow of water 6 When a check valve is used a 1 8 hole must be drilled in the PVC pip...

Страница 9: ...OLLOW THE INSTRUCTIONS ON THIS PAGE IF THE TOP OF YOUR BATTERY LOOKS LIKE PHOTO B ON PAGE 9 FOLLOW THE INSTRUCTIONS ON PAGE 9 TO FILL THE BATTERY 1 Remove the cover of the battery box by pushing in th...

Страница 10: ...erstanding the Warnings Alarms section of this manual page 11 1 The fluid in the battery is low If you are not using a PHCC Pro Series standby battery you cannot use the battery fluid sensor You will...

Страница 11: ...ITIVE post Replace the wing nuts and tighten them Slide the switch on the front of the controller to the type of battery used with the system maintenance free battery or non maintenance free battery 6...

Страница 12: ...let is bad When the problem is corrected the battery should recharge If the 5th light on the controller is also on check your main pump for failure The backup pump may have been activated repeatedly i...

Страница 13: ...ing a surge protector 10 If any of the alarms are sounding press the RED button on the front of the control panel for one 1 second REPLACING THE BATTERY Risk of electrical shock or battery explosion w...

Страница 14: ...se box for failure and correct the problem 2 Check the power cord Make sure it is securely plugged into the wall outlet Make sure the outlet is working properly 3 The control unit may have received a...

Страница 15: ...n AC pump when installing the backup pump to avoid electric shock Failure to do so could cause serious injury or death Review the safety instructions on page 1 REFER TO PHOTOS AT RIGHT 1 Unplug the Pr...

Страница 16: ...inal next to the screw marked common Turn the screw a few turns to lock in the wire If the security system requires a closing of a contact to activate the alarm secure the other wire in the terminal h...

Страница 17: ...ated brown outs Otherwise reduce the number of other appliances on the circuit Make sure the pump is securely plugged into the back of the control unit Remove strainer from pump and clean out any debr...

Страница 18: ...ted below GLENTRONICS INC at its option will either repair or replace the product and return it postage prepaid What is NOT Covered by this Warranty This warranty does not cover the cost or value of d...

Страница 19: ...and controller for reliable operation The dual float has not one but two floats mounted within a protective cage Should one float fail to operate the second float automatically activates the pump The...

Страница 20: ...2013 Glentronics Inc 1806114 05 17...

Отзывы: