Glentronics PHCC 2400 Pro Series Скачать руководство пользователя страница 12

Page 11

1

The fluid in the battery is low

Risk of electrical shock or battery explosion,
which can cause serious injury or death.
Wear eye protection.  Work in a well-
ventilated area.  Do not smoke or allow a
spark or flame in the vicinity of the battery.
Avoid dropping metal tools on the battery.
If battery acid contacts eyes, flush with
water for 15 minutes and get prompt
medical attention. Review the safety
instructions on page 1.

If this warning light and alarm are on, you need
to add distilled water to the battery.

1. Unplug the control unit power cord from the

wall outlet.

2. Remove  the  cover  of  the  battery  box  by

pushing  in  the  tabs  on  the  front  and  back,
then lifting up.

3. Fan  the  area  around  the  top  of  the  battery

with  a  piece  of  cardboard  (or  another  non-
metallic material) to remove any hydrogen or
oxygen gas that may have been emitted from
the battery.  

4. Then  unscrew  the  wing  nuts  and  remove  the

battery  cables  and  the  fluid  sensor  from  the
battery.

5. Remove the battery caps.  Add distilled water

to  the  battery  filler  bottle  and  replace  the
nozzle.  Place the battery filler into each cell
of the battery and press down.  It will fill the
battery  cell  to  the  correct  level  and  stop
automatically.    If  distilled  water  is  not
available,  tap  water  with  a  low  mineral
content  may  be  used.    Well  water  is  not
recommended.  

NEVER ADD MORE ACID.

6. Replace  the  battery  caps.    Replace  the  fluid

sensor in the hole on the top of the battery or
in  the  yellow  battery  cap,  depending  on
which  battery  you  own.    Be  sure  the  fluid
sensor  is  positioned  in  the  second  cell  from
the positive post.  The hole is marked with an
arrow. Replace the battery cables…the WHITE
wire to the NEGATIVE (-) post, and the BLACK
wire  to  the  POSITIVE  (+)  post.  Replace  the
wing nuts and tighten.

7. Replace the cover of the battery box.

8. Plug the controller back into the outlet.  (You

should  provide  additional  protection  for  the
control unit by using a surge protector.)

9. If  any  of  the  alarms  are  sounding,  press  the

RED button on the front of the control panel
for one (1) second.

2

The battery terminals are corroded or the
battery is defective

This  light  and  alarm  will  come  on  when  the
control  unit  detects  there  is  less  than  one  (1)
hour  of  pumping  power  left  in  the  battery,  or
that the battery is defective.  The alarm cannot
be silenced, because action needs to be taken to
protect your basement.  If your battery is more
than five (5) years old, replace it.  If not, here
are several situations that would cause the pump
to  run  the  battery  for  an  extended  time  and
discharge  the  battery.    Check  the  list  below
before you replace the battery.

• If  the  3rd  light  on  the  controller  is  also  on,  it

means  that  the  unit  is  not  receiving  AC  power.
Either the AC power is out, the circuit breaker has
blown, or the outlet is bad.   When the problem
is corrected, the battery should recharge.

• If the 5th light on the controller is also on,

check your main pump for failure.  The backup
pump may have been activated repeatedly if
your  main  AC  pump  is  broken,  or  you  are
experiencing heavy rains and your main pump
cannot keep up with the inflow of water.  You
may  need  to  upgrade  or  replace  your  main
pump.    When  the  problem  is  corrected,  the
battery should recharge.

• If  no  other  lights  are  on,  this  means  the

terminals  may  be  corroded,  and  the  battery
cannot  charge  properly.    Unplug  the  charger
from the wall outlet.  Then, check the battery
cables and the battery terminals for corrosion.
Clean  and  tighten  them  as  needed.    The
procedure is described in the next column.

• If  the  battery  terminals  have  been  cleaned

and  the  light  is  still  on,  there  could  be  a
problem  with  the  controller  or  the  battery.
The  best  way  to  determine  if  the  battery  is
the  problem  is  to  have  it  charged  and  load
tested at any local car service station.  If the
battery is bad and less than one (1) year old,
it can be returned to the place of purchase for
a  replacement  (receipt  required).  If  the
battery  is  good,  contact  Glentronics’  service
department  for  further  instructions.  The
phone number is 800-991-0466.

If the battery alarm goes on while the pump is
running  and  the  power  is  out,  you  will  have  a
minimum of one (1) hour of continuous pumping
time to replace the battery.  (In most cases, the
pump does not run continuously, and therefore,
you  actually  have  a  longer  time  to  replace  it.)
You will not be able to silence the alarm.  Left
unattended,  the  basement  will  flood.    In  a
severe emergency, if a replacement battery is not
available,  you  could  temporarily  use  your  car
battery, or recharge this battery by connecting it
to your car battery.

Once the AC power is restored, the battery will
recharge  automatically,  unless  it  is  old  or
damaged.  The alarm will remain on until the RED
button is pressed for one (1) second.

In  the  event  that  your  Pro  Series  sump  pump
system  has  pumped  for  an  extended  period  of
time, the battery may be very depleted.  In this
condition, when the AC power is returned to the
unit, a battery alarm will continue to sound.  The
battery  may  need  a  longer  period  to  recharge.
Press  the  RED  button  for  five  (5)  seconds  to
silence the alarm.

If  the  battery  is  completely  discharged,  an
internal safety feature will not allow the charging
system  to  activate.    Call  the  Glentronics  service
department for instructions or replace the battery.

TO CLEAN THE BATTERY
TERMINALS AND CABLES

Risk of electrical shock or battery explosion,
which can cause serious injury or death.  Wear
eye protection.  Work in a well-ventilated
area.  Do not smoke or allow a spark or flame
in the vicinity of the battery.  Avoid dropping
metal tools on the battery.  If battery acid
contacts eyes, flush with water for 15
minutes and get prompt medical attention.

!

DANGER

SURGE

PROTECTOR

8

9

POSITIVE

POST

NEGATIVE

POST

6a

3

4

Remove

5

2

6b

!

DANGER

Содержание PHCC 2400 Pro Series

Страница 1: ...ction to existing discharge for narrow sumps 7 Battery Instructions 8 9 Control Unit Connections Positioning the float switch 9 Connecting the pump 9 Installing the battery fluid sensor 10 Connecting...

Страница 2: ...ntronics Inc 645 Heathrow Drive Lincolnshire IL 60069 4205 BATTERY PREPARATION Sulfuric acid can cause blindness or severe burns Avoid contact with skin eyes or clothing In the event of an accident fl...

Страница 3: ...battery with this system It will not run the pump as long as the Pro Series 2200 or B12 90 battery The internal construction of some wet cell batteries may not be compatible with this system Glentron...

Страница 4: ...e main AC pump Try to fit the backup pump on the floor of the sump first Make sure there is enough room so the backup pump and the main pump do not touch each other Select the installation method that...

Страница 5: ...ia the shortest path with the fewest turns More turns will reduce the pumping capacity The pipe section exiting the building should be on a downward slope so that the water in the pipe will exit outsi...

Страница 6: ...lled at this time Cut the discharge pipe approximately one 1 foot above the floor Install a check valve on the top of the pipe and tighten the bottom hose clamp Now prime and cement a small piece of 1...

Страница 7: ...he details of each installation will vary Using sound plumbing practices route the discharge pipe to an exterior wall via the shortest path with the fewest turns More turns will reduce the pumping cap...

Страница 8: ...attached to the Pro Series pump Make sure it is installed with the arrow pointing up or it will not prevent the backflow of water 6 When a check valve is used a 1 8 hole must be drilled in the PVC pip...

Страница 9: ...OLLOW THE INSTRUCTIONS ON THIS PAGE IF THE TOP OF YOUR BATTERY LOOKS LIKE PHOTO B ON PAGE 9 FOLLOW THE INSTRUCTIONS ON PAGE 9 TO FILL THE BATTERY 1 Remove the cover of the battery box by pushing in th...

Страница 10: ...erstanding the Warnings Alarms section of this manual page 11 1 The fluid in the battery is low If you are not using a PHCC Pro Series standby battery you cannot use the battery fluid sensor You will...

Страница 11: ...ITIVE post Replace the wing nuts and tighten them Slide the switch on the front of the controller to the type of battery used with the system maintenance free battery or non maintenance free battery 6...

Страница 12: ...let is bad When the problem is corrected the battery should recharge If the 5th light on the controller is also on check your main pump for failure The backup pump may have been activated repeatedly i...

Страница 13: ...ing a surge protector 10 If any of the alarms are sounding press the RED button on the front of the control panel for one 1 second REPLACING THE BATTERY Risk of electrical shock or battery explosion w...

Страница 14: ...se box for failure and correct the problem 2 Check the power cord Make sure it is securely plugged into the wall outlet Make sure the outlet is working properly 3 The control unit may have received a...

Страница 15: ...n AC pump when installing the backup pump to avoid electric shock Failure to do so could cause serious injury or death Review the safety instructions on page 1 REFER TO PHOTOS AT RIGHT 1 Unplug the Pr...

Страница 16: ...inal next to the screw marked common Turn the screw a few turns to lock in the wire If the security system requires a closing of a contact to activate the alarm secure the other wire in the terminal h...

Страница 17: ...ated brown outs Otherwise reduce the number of other appliances on the circuit Make sure the pump is securely plugged into the back of the control unit Remove strainer from pump and clean out any debr...

Страница 18: ...ted below GLENTRONICS INC at its option will either repair or replace the product and return it postage prepaid What is NOT Covered by this Warranty This warranty does not cover the cost or value of d...

Страница 19: ...and controller for reliable operation The dual float has not one but two floats mounted within a protective cage Should one float fail to operate the second float automatically activates the pump The...

Страница 20: ...2013 Glentronics Inc 1806114 05 17...

Отзывы: