![Glensound Express IP MKII Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/glensound/express-ip-mkii/express-ip-mkii_product-details_2231619018.webp)
Page
18
of
24
3.
Receiving AES67 Audio
Once a compatible AES67 stream is detected on the network by Dante Controller the
AES67 flows will appear in the Dante Transmitters section in the Routing tab.
4.
AES67 Restrictions
AES67 flows can only be generated with the following constraints:
Multicast Only
Non-redundant
Destination address in range 239.nnn.0.0 to 239.nnn.255.255 (239.nnn/16),
port 5004
48kHz sampling rate
24 bit linear (L24) encoding
1 msec packet time
Up to 8 channels per stream
Received AES67 flows have the following constraints:
Multicast Only
Non-redundant
Destination address in range 239.nnn.0.0 to 239.nnn.255.255 (239.nnn/16),
port 5004. Must match destinatio address range.
48kHz sampling rate
L16 or L24 encoding
125usec, 250usec, 333usec, 1 msec packet time
Up to 8 channels per stream