Glendinning HoseMaster Скачать руководство пользователя страница 5

6

5

M

AINTENANCE

T

ROUBLE

S

HOOTING

G

UIDE

The HoseMaster was designed for longevity of operation with very little maintenance required. When dealing with a

drinking water safe device, it is extremely important to keep exposed parts that come into contact with your potable water
free of debris or contaminates. With each use of the HoseMaster always 

REPLACE THE HOSE CAP

when the water hose

is disconnected from a supply source. 

CHECK TO MAKE SURE NOTHING IS RUBBING

or binding on the storage spool.

CHECK ALL WIRING CONNECTIONS, 

at least once a year, to be sure they are secure and free of corrosion.

COMPLAINT

Non-functional
(either no power or
unit has power and
does not respond)

Tripped breaker

Blown fuse at power source

Power wire incorrectly con-
nected to power source

Defective motor

z

z

z

z

Reset breaker

Check power source fuse and connections, recon-
nect or replace if necessary

With power switch on and voltage across motor wires
— if no response, replace motor

z

z

z

HoseMaster stops
retracting while but-
ton is being pushed

Hose jammed during retraction
causing breaker to trip

z

Reset breaker

Pay out hose and rewind

z

z

Pays out hose only

Power inputs reversed

z

Check polarity on DC input wires

z

PROBABLE CAUSE

RECOMMENDED ACTION

E

F

O

PERATING

I

NSTRUCTIONS

To operate the 

HoseMaster

, follow these steps:

— 

PULL OUT ONLY

the amount of hose required to reach the dockside water supply bib.

— 

TURN ON

the dockside water supply to remove any standing water, then turn OFF.

— 

REMOVE

the HoseMaster’s hose cap and inspect gasket.

— 

SCREW THE FEMALE HOSE FITTING

onto the dockside water supply bib until leak-tight.

(use 51564 (optional accessory) at docks with high supply pressures to protect  your vessel’s system)

— 

TURN ON

the dockside water supply. Ship is now being equipped with water from dockside supply.

When ready to get underway:

— 

TURN OFF

dockside water supply and release 

hose pressure by disconnecting hose from supply.

— 

INSPECT HOSE CAP

for contamination; clean if 

necessary and screw hose cap onto water hose.

— 

PUSH AND HOLD

the 

HoseMaster

power switch  

(red button). 

HoseMaster

will electrically retrieve the water hose and store it on the self winding wheel.

— When hose has been retracted, 

RELEASE

the push-button power switch to stop the unit 

(continuing to push

the  power button may cause damage to the motor and will cause the circuit breaker switch to trip—reset before 

next use)

.

Hose Guide

adjusts to 5

positions 

yeilding greater
flexibility during

installation

Follow these steps:

1—Remove the (4) bracket nuts on the face of the hose 

guide. 

Be careful not to remove the bolts.

2—Remove the adjustable hose guide.
3—Reinstall hose guide arm by aligning bolts to holes when 

at desired position.

4—Carefully replace hose guide and attach the (4)     

bracket nuts 

(step 1)

. Tighten all nuts on hose guide.

A

DJUSTABLE

H

OSE

G

UIDE

(

SEE BELOW ON HOW TO

ADJUST

)

*Add 3” to allow for

installation connection

13.00”

14.00”

*12.00”

H

OSE

M

ASTER

D

IMENSIONS

G

H

OW TO

A

DJUST THE

H

OSE

G

UIDE

What you will need:

—7/16” socket wrench
—7/16” open-end wrench

*Cordless drill optional

1

2

3

4

5

REMEMBER:

Always disconnect AND fully retract your water

hose BEFORE getting underway!

D

Keep the female hose hookup clean at 

all times to avoid contamination. Keep the 

hose cap (pg. 2) installed whenever the hose is 

disconnected from a supply bib!

Отзывы: