5.2 Burner and Nozzle Data Table
GAS CATEGORY:
I3+(28-30/37)
I3B/P(30)
I3B/P(37)
I3B/P(50)
TYPES OF GAS:
□G30
□G31
□G30
□G30
□G30
GAS PRESSURE
(
mbar
)
: 29
37
29
37
50
HEAT
INPUT(Hs)
Top burner:
1.7kW(124g/h)
Bottom burner:
2.5kW(182g/h)
Top burner:
1.7kW(124g/h)
Bottom
burner:
2.5kW(182g/h)
Top burner:
1.7kW(124g/h)
Bottom burner:
2.5kW(182g/h)
Top burner:
1.5kW(109g/h)
Bottom burner:
2.5kW(182g/h)
INJECTOR SIZE
Top :0.65mm
Bottom :0.77m
m
Top :0.65mm
Bottom :0.77m
m
Top :0.65mm
Bottom :0.71m
m
Top :0.50mm
Bottom :0.65m
m
GAS CATEGORY:
I2H
I2E
I2E+
I2L
TYPES OF GAS:
□G20
□G20
□G20
□G25
□G25
GAS PRESSURE
(
mbar
)
: 20 mbar
20 mbar
20
25
25
HEAT:
INPUT(Hs)
Top
burner:1.5kW
Bottom
burner:2.6kW
Top
burner:1.5kW
Bottom
burner:2.6kW
Top
burner:1.5kW
Bottom
burner:2.6kW
Top
burner:1.5kW
Bottom
burner:2.6kW
INJECTOR SIZE
Top :0.93mm
Bottom :1.18m
m
Top :0.93mm
Bottom :1.18m
m
Top :0.93mm
Bottom :1.18m
m
Top :0.93mm
Bottom :1.18m
m
VOLTAGE / FREQUENCY
:
AC220-240V/50-60Hz
ELECTRIC POWER
:
1.8kW
I3+(28-30/37)
I3B/P(30)
I3B/P(37)
I3B/P(50)
I2H
I2E
I2E+
I2L
Ⅱ
2H3B/P
✔
✔
Ⅱ
2H3+
✔
✔
Ⅱ
2E+3+
✔
✔
Burner
Rated heat
capacity
(kW)
BOTTLED GAS - G30/G31
28/37 mbar
Nozzle
diameter
1/100 mm
By-pass
1/100
mm
Reduced
heat capacity
(W)
Flow-rate
g/h G30
Flow-rate
g/h G31
Oven
2.5
77
41
700
189
186
Burner
Rated heat
capacity
(kW)
NATURAL GAS - G20
20 mbar
Nozzle diameter
1/100mm
Reduced heat capacity
(W)
Oven
2.6
118
700
6. DESCRIPTION OF FRONT PANEL CONTROLS
All the cooker's control and monitoring devices are placed together on the front panel. The table below
provides the key to the symbols used.
Содержание GL 662 Gas
Страница 1: ...USER S GUIDE BUILT IN OVEN GL662Gas ...