Section 7 Fitting 

the Cover into 

Position 

 

 

It is necessary to engage the control knob 

on the correct position on the valve spindle 

before the front cover is located. 

 

1.

 

Before replacing the front cover check that the 

valve spindle and temperature control knob 

are set to fully anti clockwise or full flow. 

 

2.

 

Secure the front cover with the two screws. 

 

Important information 

 

Ensure the rotary temperature control is 

positioned fully anti clockwise and that the valve 

is fully open.   

 

Section 8 

Commissioning 

Procedure 

 

1.

 

Switch on the mains electrical supply at the 

isolating switch. 

 

2.

 

Ensure the water supply is fully on at the 

mains and the isolating service valve (if fitted) 

is fully open. 

 

3.

 

Place hand in front of the sensor lens 

approximately 150mm away, the unit will 

start. 

 

4.

 

Check that the water flows freely from the 

handwash within a few seconds                                        

 

5.

 

Check that the unit switches off automatically 

after approximately 30 seconds  

 

 

 

6.

 

Now switch off the power supply at the local 

isolator and then remove the front cover. 

 

7.

 

Remove the RED LOCK MOULDING by sliding 

it upwards and away from the pressure 

switch. 

 

8.

 

Check for leaks 

 

9.

 

Refit the front cover. 

 

10.

 

Switch the power on at local isolator 

 

11.

 

Place hand in front of sensor to restart unit 

and adjust temperature control knob to a 

desired temperature. Allow a few moments 

for the temperature to stabilize. 

 

12.

 

Turn control knob anti clockwise to check 

water gets cooler 

 

Section 9 Operating 

the Handw ash 

 

1.

 

The mains electricity and water supply should  

normally be left on.                                                                                                                                                                                         

 

2.

 

To operate the handwash, simply pass your 

hand in front of the central sensor lens. The 

unit has an infra-red beam which when 

reflected by your hand switches the unit on. 

The unit can be switched off by the same 

action. The unit will shut down after 30 

seconds. 

 

3.

 

Water is heated instantaneously as it flows 

over the heating elements in the heat 

exchanger.                                                    

 

4. The flow/temperature is adjusted via the 

control knob, the higher the flow the lower 

the temperature and the lower the flow the 

higher the temperature.                                           

 

Wait a few moments for the 

temperature of the water to stabilize.  

                                            

 

4.

 

If the incoming water pressure falls below a 

set limit, the pressure switch will operate and 

switch off the power to the heating element 

 

Содержание Redring RAHW3

Страница 1: ...Automatic Handwash RAHW3 IMPORTANT This booklet should be left with the user after installation and demonstration...

Страница 2: ...own dedicated supply however it can be connected with a 13amp socket and plug This appliance must NOT be fitted where it may be subjected to freezing conditions Isolate the mains electrical and water...

Страница 3: ...oving the front cover check that the rotary temperature control is set to fully anticlockwise or full flow 2 Remove the two screws top and bottom securing the handwash unit cover and remove the cover...

Страница 4: ...1 5mm double insulated cable The cable can be surface clipped hidden or via conduit 4 The incoming cable access to the handwash unit is located at the top bottom or rear of the unit on the right hand...

Страница 5: ...r 7 Remove the RED LOCK MOULDING by sliding it upwards and away from the pressure switch 8 Check for leaks 9 Refit the front cover 10 Switch the power on at local isolator 11 Place hand in front of se...

Страница 6: ...the end of the spray arm with a small stiff bristled brush If the deposits are stubborn remove the central spray rings with the central screw and immerse in a lime scale remover solution Section 11 T...

Страница 7: ...13 Energy Related Product Directive ErP Supplier Manufacturer Redring Product Auto Handwash Supplier Model Number RAHW3 Load Profile 3XS Efficiency Class A Efficiency 38 Consumption kwh annum 81 Soun...

Страница 8: ...e expiry date The warranty on any exchanged parts or product ends when the original guarantee period ends EXCLUSIONS This warranty DOES NOT cover damage or defects arising from poor or incorrect insta...

Отзывы: