Section 7 Fitting
the Cover into
Position
It is necessary to engage the control knob
on the correct position on the valve spindle
before the front cover is located.
1.
Before replacing the front cover check that the
valve spindle and temperature control knob
are set to fully anti clockwise or full flow.
2.
Secure the front cover with the two screws.
Important information
Ensure the rotary temperature control is
positioned fully anti clockwise and that the valve
is fully open.
Section 8
Commissioning
Procedure
1.
Switch on the mains electrical supply at the
isolating switch.
2.
Ensure the water supply is fully on at the
mains and the isolating service valve (if fitted)
is fully open.
3.
Place hand in front of the sensor lens
approximately 150mm away, the unit will
start.
4.
Check that the water flows freely from the
handwash within a few seconds
5.
Check that the unit switches off automatically
after approximately 30 seconds
6.
Now switch off the power supply at the local
isolator and then remove the front cover.
7.
Remove the RED LOCK MOULDING by sliding
it upwards and away from the pressure
switch.
8.
Check for leaks
9.
Refit the front cover.
10.
Switch the power on at local isolator
11.
Place hand in front of sensor to restart unit
and adjust temperature control knob to a
desired temperature. Allow a few moments
for the temperature to stabilize.
12.
Turn control knob anti clockwise to check
water gets cooler
Section 9 Operating
the Handw ash
1.
The mains electricity and water supply should
normally be left on.
2.
To operate the handwash, simply pass your
hand in front of the central sensor lens. The
unit has an infra-red beam which when
reflected by your hand switches the unit on.
The unit can be switched off by the same
action. The unit will shut down after 30
seconds.
3.
Water is heated instantaneously as it flows
over the heating elements in the heat
exchanger.
4. The flow/temperature is adjusted via the
control knob, the higher the flow the lower
the temperature and the lower the flow the
higher the temperature.
Wait a few moments for the
temperature of the water to stabilize.
4.
If the incoming water pressure falls below a
set limit, the pressure switch will operate and
switch off the power to the heating element