Section 3 

Handw ash 

Installation 

 

The unit should be sited so that all the spray is 

contained in the sink. 

 

We recommend that a WRAS (Water Regulations 

Advisory Scheme) listed isolating valve is fitted 

into the mains cold water supply for servicing 

purposes. 

 

WARNING:  

ALL WIRING AND INSTALLATION MUST 

BE SUPERVISED BY A SUITABLY 

QUALIFIED PERSON. 

 

DO NOT INSTALL THIS UNIT 

WHERE IT MAY BE SUBJECTED TO

 

FREEZING CONDITIONS.

 

 

USE ONLY THE COLD RISING WATER 

MAIN SUPPLY. 

DO NOT CONNECT THE HANDWASH 

UNIT TO THE DOWN SERVICE FROM A 

COLD WATER STORAGE TANK.

 

 

Section 4 Plumbing 

Connection 

 

 

Plumbing the handwash unit must precede 

making electrical connections. 

 

The handwash unit must be connected to the 

cold water supply with a minimum running 

pressure of 69 kPa (0.7 bar, 10 psi) and a 

maximum pressure of 690 kPa (7.0 bar, 100 psi). 

 

Turn off the water supply at the isolating tap. 

 

Ø15mm copper, chrome polished, stainless steel 

pipe or plastic pipe with a 15mm compression 

elbow or push fit. should be used.                                                     

Ensure that there are no burrs on the pipe.              

 

 

 

1.

 

Before removing the front cover check that 

the rotary temperature control is set to fully 

anticlockwise or full flow 

 

2.

 

Remove the two screws top and bottom 

securing the handwash unit cover and remove 

the cover complete. 

 

3.

 

Place the handwash unit on the wall and 

determine the entry position of the water inlet 

supply pipe. 

 

                                                                   

4.

 

Mark the location of the fixing screws through 

the backplate. Need correct picture                                                   

 

Drill the top two and bottom screw entry 

points and insert wall plugs provided. 

 

5.

 

Align the unit to the screw entry points 

Tighten the top screw with head protruding 

about 10mm from the wall and hook the 

backplate over the screw head.                                   

 

This allows for correct and accurate alignment 

of the handwash unit before fixing the bottom 

position. 

                                                                 

6.

 

Secure the unit to the wall. The slots are 

elongated to allow for final adjustment. 

 

7.

 

Before completing the connection of the water 

supply to the inlet of the unit, ensure you 

flush out the pipework to remove all swarf and 

system debris. 

 

8.

 

Connect the mains water supply to the inlet of 

the handwash unit using the relevant Ø15mm 

pipe, copper pipe, stainless steel or plastic 

pipe with a 15mm compression elbow or push 

fit. 

 

9.

 

Check for leaks 

                                                                                    

Do not use excessive force when making 

the connection to the unit.                          

 

 

Содержание Redring RAHW3

Страница 1: ...Automatic Handwash RAHW3 IMPORTANT This booklet should be left with the user after installation and demonstration...

Страница 2: ...own dedicated supply however it can be connected with a 13amp socket and plug This appliance must NOT be fitted where it may be subjected to freezing conditions Isolate the mains electrical and water...

Страница 3: ...oving the front cover check that the rotary temperature control is set to fully anticlockwise or full flow 2 Remove the two screws top and bottom securing the handwash unit cover and remove the cover...

Страница 4: ...1 5mm double insulated cable The cable can be surface clipped hidden or via conduit 4 The incoming cable access to the handwash unit is located at the top bottom or rear of the unit on the right hand...

Страница 5: ...r 7 Remove the RED LOCK MOULDING by sliding it upwards and away from the pressure switch 8 Check for leaks 9 Refit the front cover 10 Switch the power on at local isolator 11 Place hand in front of se...

Страница 6: ...the end of the spray arm with a small stiff bristled brush If the deposits are stubborn remove the central spray rings with the central screw and immerse in a lime scale remover solution Section 11 T...

Страница 7: ...13 Energy Related Product Directive ErP Supplier Manufacturer Redring Product Auto Handwash Supplier Model Number RAHW3 Load Profile 3XS Efficiency Class A Efficiency 38 Consumption kwh annum 81 Soun...

Страница 8: ...e expiry date The warranty on any exchanged parts or product ends when the original guarantee period ends EXCLUSIONS This warranty DOES NOT cover damage or defects arising from poor or incorrect insta...

Отзывы: