Conversion Instructions
This conversion kit is for use on the following appliances:
Dual Fuel - all sizes.
This conversion kit is to be used to convert the above appliances from:
UK Appliance Nat Gas to LP
- Natural Gas G20 @ 20mbar to LPG G30/31 @
29/37mbar
UK Appliance LP to Nat Gas
- LPG G30/31 @ 29/37mbar to Natural Gas G20 @
20mbar
UK to German LPG
G30/G31 @ 50 mbar
UK to Australian NG
@ 1.0kPa
UK to Australian ULPG
@2.75kPa
Before beginning conversion, ensure that the Gas and Electricity supplies have been
turned off. The full conversion must be completed - i.e. you must change the injectors
and
the by-pass pins.
Important:
The conversion procedure must be carried out by a suitably qualified person
i.e. Corgi registered. After conversion all affected parts must be checked for gas sound-
ness.
Injectors & Bypass Screws
UK / Europe NG
Hotplate burner
Auxiliary ( Small)
Semi Rapid
(Medium)
Rapid (Large)
Wok
Inner
Outer
Injector
77
104
129
63
121
UK / Europe LP (Excluding Germany)
Hotplate burner
Auxiliary ( Small)
Semi Rapid
(Medium)
Rapid (Large)
Wok
Inner
Outer
Injector
50
70
87
35
87
Germay LP
Hotplate burner
Auxiliary ( Small)
Semi Rapid
(Medium)
Rapid (Large)
Wok
Inner
Outer
Injector
46
61
79
35
77
Australian NG
Hotplate burner
Auxiliary ( Small)
Semi Rapid
(Medium)
Rapid (Large)
Wok
Inner
Outer
Injector
82
118
142
72
138
Bypass
63
63
77
Australian ULPG
Hotplate burner
Auxiliary ( Small)
Semi Rapid
(Medium)
Rapid (Large)
Wok
Inner
Outer
Injector
50
70
87
35
87
Bypass
32
39
45
80
43
Содержание Belling 110DF
Страница 1: ...1 BELLING RICHMOND 1100 DF SERVICE MANUAL...
Страница 4: ......
Страница 58: ...1 B BELLING RICHMOND 110 DF REPAIR AND MAINTAINANCE PROCEDURES...
Страница 59: ...2 IMPORTANT BEFORE CARRYING OUT ANY SERVICING WORK ALWAYS DISCONNECT FROM THE ELECTRICAL SUPPLY...
Страница 79: ...22 BELLING RICHMOND 110DF FAULTFINDING GUIDES...