background image

For Your Safety

Carefully read the following important information regarding
installation safety and maintenance. Keep this information booklet
accessible for future reference.

This appliance has been designed for use in a Ducted or
Recirculating installation.

Optional Accessories:

Models AAS6SE3, AAS9SE3, CP6BLS, CP9BLS, CP9BLB 
Recirculating Kit: IA150BSRK
Carbon Filter: CF110

Models AAG6SE1, AAG9SE3.
Recirculating Kit: IA150GRK
Carbon Filter: CF110

Models RFT6, RFT9, RGT6, RGT9
Recirculating Kit: IA150BRK
Carbon Filter: CF260

Safety Precautions

Take care when the Range Hood is operating simultaneously with
an open fireplace or burner that depend on natural ventilation as
the Range Hood removes air from the room, which a burner or
fireplace may need for combustion.

Provide adequate ventilation for  safe operation of the Range
Hood. Follow any local laws that apply to external air evacuation.

Before connecting to the electricity network:

Look at the data plate (located inside the appliance) to ascertain
that the voltage and power correspond to the available power
supply and the power outlet is suitable. If in doubt ask a qualified
electrician.

If the appliance is used intensively for a long period of time, you
may need to opening a window to improve airflow.

3

Содержание AAG6SE1

Страница 1: ...MBTT 8BMM BOPQZ 4 4 4 4 DN 1ZSBNJE 8BMM BOPQZ 4 4 4 4 DN 1ZSBNJE 8BMM BOPQZ 4 4 1 4 DN 1ZSBNJE 8BMM BOPQZ 4 4 1 4 DN 1ZSBNJE 8BMM BOPQZ 4 4 1 DN 1ZSBNJE 8BMM BOPQZ MBDL 3 5 DN MBU 8BMM BOPQZ 4 4 3 5 D...

Страница 2: ...d Care 6 LED Lamps 6 Operating Instructions 7 Cleaning your rangehood 9 Installing the carbon filter 10 Installation 12 Electrical Connection 12 Instructions for Installation 13 Fixing to the wall 14...

Страница 3: ...cautions Take care when the Range Hood is operating simultaneously with an open fireplace or burner that depend on natural ventilation as the Range Hood removes air from the room which a burner or fir...

Страница 4: ...ith reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible f...

Страница 5: ...hob and the lowest part of the range hood shall be at least 60cm If the instructions for installation of the gas hob specify a greater distance this has to be taken into account Regulation concerning...

Страница 6: ...the Range Hood continues to operate effectively regular maintenance and cleaning is required Clean the fan and other surfaces of the Range Hood regularly using a cloth moistened with warm water or no...

Страница 7: ...in 5 The rangehood can be switched off by pushing the POWER button once to firstly cease operation of the motor and then a second time to power down the unit AAS6SE3 AAS99SE3 AAG6SE1 AAG9SE3 Operating...

Страница 8: ...urn the motor off and then once again to power down the rangehood 5 The lights can be switched on or off at any time by pushing the LIGHT button SETTING THE COUNTDOWN TIMER The rangehood features a co...

Страница 9: ...nstructions Remove the filters from the cooker hood and wash them in a solution of water and neutral liquid detergent leaving to soak Rinse thoroughly with warm water and leave to dry The filters may...

Страница 10: ...ner depending on how frequently the rangehood is used otherwise the performance of the rangehood can be impeded 1 If the rangehood has a perimeter panel then pull down to reveal the mesh filters other...

Страница 11: ...otherwise the performance of the rangehood can be impeded 1 Push the handle of the aluminum mesh filters towards the rear of the rangehood until they re released from the housing and then remove them...

Страница 12: ...appliance has been manufactured as a class I therefore earth cable is necessary The connection to the mains is carried out as follow If not provided connect a plug for the electrical load indicated o...

Страница 13: ...for the evacuation of the air Installation 650 750 Rangehood Cooking Surface Recommended Clearances Install Range Hoods in accordance with the manufacturer s instructions For optimum performance we r...

Страница 14: ...where necessary to ensure rangehood is properly secured against the wall For various installation types use screws and screw anchors suited to the type of wall e g reinforced concrete plasterboard etc...

Страница 15: ...Installation 15...

Страница 16: ...p of the range hood C D Ducted installation Connect the ductwork to the outlet with a cable tie or suitable tape Do not use screws Recirculated installation The air will vent out through the vents in...

Страница 17: ...equences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The symbol on the product indicates that this product may not be treated a...

Страница 18: ...pairs must be carried out by Glen Dimplex or their nominated service agent Note warranty periods detailed above may vary in line with agreements with select retail and builder partners and may differ...

Страница 19: ...ired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure 4 How to make a claim You may make a claim under this warranty through our website con...

Страница 20: ...le Goods presented for repair may be replaced by refurbished goods of the same type rather than being repaired Refurbished parts may be used to repair the goods Products are designed and supplied for...

Страница 21: ...__________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________...

Страница 22: ...__________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________...

Страница 23: ...__________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ________________...

Страница 24: ...d building codes with compliance being issued as required by state or national legislation Additionally all upright cookers must have the anti tilt device installed correctly in adherence to the relev...

Отзывы: