background image

www.gdts.one

DOK4x HOIAO WxDEN · FD 9912

31

Air-to-water heat pump 6 kW

English

15 Warranty certificate

Glen Dimplex Thermal Solutions

Warranty certificate - System M
(heating heat pumps, central domestic ventilation units)
Valid for Germany and Austria
(issued 11/2019)

The following conditions, describing the requirements and the
scope of our warranty service, do not affect the warranty obliga-
tions of the seller arising from the sales contract with the end cus-
tomer. We offer a warranty for the units subject to the following
conditions:

Based on the following conditions, we remedy defects on the unit
due to material and/or manufacturing defects free of charge, pro-
vided they are reported to us without delay upon being detected
and within 24 months after delivery to the first end customer. This
period is 12 months for spare parts and for commercial use.

This unit is only covered by this warranty if it was purchased by a
customer in one of the member states of the European Union, it is
being operated in Germany or Austria when the defect occurs, and
warranty services can also be rendered in Germany or Austria.

Defects we have recognised as being covered by the warranty are
remedied by free repair of the defective parts at our discretion or re-
placement with fault-free parts. We do not cover exceptional costs
of remedying defects due to the type or location of the unit's use or
poor accessibility of the unit. The customer must ensure free ac-
cess to the unit. Dismantled parts which we take back become our
property. The warranty period for rework and spare parts ends with
the expiration of the original warranty period for the unit. The war-
ranty does not cover easily breakable parts which have only an in-
significant effect on the value or usability of the unit. The original
purchase receipt, with purchase or delivery date, must always be
presented.

The warranty becomes void if the customer or a third party has
failed to comply with the applicable VDE regulations, the regula-
tions issued by local utility companies or our installation and oper-
ating instructions, or the information on maintenance work and the
installation diagrams included in the project planning documents,
or if the accessories required for proper functioning have not been
used. We accept no liability for the consequences of modifications
and work activities performed improperly by the end customer or a
third party. The warranty covers the unit and the parts purchased
from the supplier. Parts and units not purchased from the supplier,
and unit/system defects due to parts not purchased from the sup-
plier are not covered by the warranty.

If it was not possible to remedy the defect, the manufacturer shall
either deliver a replacement free of charge or issue a reimburse-
ment for the reduced value. In cases in which replacement is pro-
vided, we reserve the right to apply a reasonable utilisation charge
for the period of usage elapsed to date. Additional or further claims,
in particular regarding compensation for damage caused outside of
the unit, are excluded.

It is possible to extend the warranty under certain conditions by tak-
ing out a Care Basic warranty package (extension from 2 to 5 years).
For further details, visit: 
https://gdts.one/building-climate-solutions/waermepumpen/sys-
tem-m/service

The prerequisite for accepting the extended warranty is chargeable
commissioning by the authorised after-sales service for complete
systems (see fixed charges in the service price list) with an opera-
tional suitability assessment within an operating time (compressor
runtime) of less than 150 hours. The chargeable assessment of op-
erational suitability by the after sales service for complete systems
is ordered in writing using the corresponding order form or using
the online order facility on the Internet (www.dimplex.de/garantiev-
erlaengerung). Complete payment of the fixed charge is a prerequi-
site for confirmation of the warranty time extension. If any defects
are noted in the operational suitability assessment log, they must
be remedied. The warranty time extension is confirmed from the
address specified below after successful assessment of operational
suitability and submission of the log by the after sales service for
complete systems to GDTS. The prerequisite is a review of the data
in the operational suitability assessment log and approval by GDTS.
The warranty ends at the latest 72 months from delivery from the
factor or 78 months from the date of manufacture.

The fixed charge includes the work performed to assess operational
suitability plus travel costs. No liability is assumed for proper plan-
ning, dimensioning and execution of the overall system. Remedying
system defects and waiting times are extra services.

The current fixed rates and the associated services can be found on
the Internet at: http://www.dimplex.de/garantieverlaengerung.
There is also an online order form here.

Glen Dimplex Thermal Solutions

Glen Dimplex Deutschland GmbH
Department: Service
Am Goldenen Feld 18
95326 Kulmbach

For order processing, the 

type

, the 

serial number S/N

, the date of

manufacture 

FD

 and, if specified, the customer service index 

KI

 for

the unit are required.
This information is listed on the unit’s type plate.

After-sales service address:

Tel:
Fax no.:
E-mail address:
Internet:

+49 (0)9221 709 545
+49 (0)9221 709 924545
[email protected]
www.gdts.one
www.dimplex.de/garantieverlaengerung
www.dimplex.de/seviceauftrag

Содержание 06CHOIAOC6

Страница 1: ...er no DOK4x HOIAO WxDEN EN FD 9912 System M Compact Plus 6kW Installation and Operating Instruction Air to Water Heat Pump in Integral Design Glen Dimplex Thermal Solutions Dimplex 06CHOIAOC6 06IHOIAO...

Страница 2: ......

Страница 3: ...e 11 6 2 Condensate drain 11 6 3 Connection on heating side 11 6 4 Domestic hot water connection 12 6 5 Temperature sensor connection 13 6 6 Electrical connection 14 6 7 Refrigerant pipe connections 1...

Страница 4: ...2 DOK4x HOIAO WxDEN FD 9912 www gdts one English Air to water heat pump 6 kW 17 Declaration of conformity 33...

Страница 5: ...to This unit can be used by children aged 8 and over and by per sons with limited physical sensory or mental aptitude or lack of experience and or knowledge providing they are supervised or have been...

Страница 6: ...the air i e ex tracts heat from it This extracted heat is then transferred to the working medium refrigerant in the evaporator The heat is pumped to a higher temperature level by increas ing its pres...

Страница 7: ...lve for generating domestic hot water 9 Switch box with heating controller 10 Overflow valve to guarantee the minimum heating water flow rate to be set by the installer 11 Universal hardware interface...

Страница 8: ...6 DOK4x HOIAO WxDEN FD 9912 www gdts one English Air to water heat pump 6 kW 3 2 Outdoor unit 1 Evaporator 2 Fan 3 Expansion valve 4 Switch box 5 Connection for refrigerant line 1 2 3 4 5...

Страница 9: ...be tilted back by up to 45 and lifted by the handles on the back at the top Tilting over 45 is not permitted without removing the refrigeration circuit beforehand To remove the refrigeration circuit r...

Страница 10: ...onnection 2 Disconnect the plug connections on the refrigeration cir cuit switch box 3 Loosen the mounting screws 4 Pull the refrigeration circuit out at the side and transport it to the intended loca...

Страница 11: ...The responsibility for the heat pump in stallation lies with the specialist system construction company During the installation local requirements such as building reg ulations static load of the bui...

Страница 12: ...on location at any time of the year The minimum volume of the room where the heat pump is in stalled must be no less than the following value depending on the refrigerant quantity in the device If the...

Страница 13: ...and shut off option must be im plemented upstream and downstream of the indoor unit Once the heat pump has been connected to the heating sys tem it must be filled purged and pressure tested When doin...

Страница 14: ...e ready for op eration The system must be drained if the heat pump is taken out of service or in the event of a power failure The heating cir cuit should be operated with a suitable frost protection i...

Страница 15: ...at all weather conditions are taken into consideration and the meas ured value is not falsified Mount on the external wall on the north or north west side where possible Do not install in a sheltered...

Страница 16: ...OK4x HOIAO WxDEN FD 9912 www gdts one English Air to water heat pump 6 kW 6 6 Electrical connection 6 6 1 Circuit diagram Symbol legend see cap 6 6 2 on page 15 Equipment marking see cap 6 6 3 on page...

Страница 17: ...ydraulics WPM A210 Master unit A220 Expansion module WPM A300 Electrical distribution system A350 Router A400 Hydraulic installation general A420 Domestic hot water B3 domestic hot water thermostat E1...

Страница 18: ...old cur rent because otherwise important protection functions could be lost during a utility block Utility block The utility blocking contactor K22 with main contact and auxiliary contact NO contact 1...

Страница 19: ...75 g 225 g HINWEIS NOTE If the indoor unit is mounted 2 5 m or more metres higher or lower than the outdoor unit a cooling technology specialist must perform a separate check to ensure that the device...

Страница 20: ...the system Step 1 Preparation Ensure that every pipe liquid and intake side between the in door and outdoor unit is connected correctly Ensure that both maintenance valves on the liquid and intake of...

Страница 21: ...ss varies with differ ent lengths of the pipework and the pump output The follow ing table shows the time required for pumping empty Step 4 Filling Once the leakage tightness test and evacuation have...

Страница 22: ...ing procedure to set the over flow valve correctly Close all heating circuits that may also be closed during opera tion depending on how the heat pump is being used so that the most unfavourable opera...

Страница 23: ...by a heating technician Based on current information we recommend using a 5 phosphoric acid solution for cleaning purposes However if cleaning needs to be performed more frequently a 5 formic acid sol...

Страница 24: ...rom the power supply HINWEIS NOTE Personal protective equipment protective goggles safety shoes and gloves where necessary must be used when work ing on the device Components with plastic parts must b...

Страница 25: ...nce of 1 m indoors4 dB A 38 38 3 7 Air flow Normal operation reduced operation3 m h 3000 2600 3000 2600 4 Dimensions weight and filling quantity 4 1 Device dimensions5 indoors without connections H x...

Страница 26: ...system other parameters in particular the defrosting capacity the bivalence point and regulation should also be taken into consideration These figures are only achieved with clean heat exchangers Info...

Страница 27: ...intake 0 3 m 1 0 m 0 5 m 0 5 m Minimum clearances Direction of air flow 358 40 460 40 17 5 4x Fixing holes base frame for M12 438 540 Hatched area footprint 600 871 500 165 40 40 53 36 676 472 99 160...

Страница 28: ...2 www gdts one English Air to water heat pump 6 kW 12 2 Dimension drawing indoor unit 2 1 2 6 2 8 2 7 2 3 2 4 2 5 2 2 544 600 600 2100 0 40 142 212 282 352 422 573 652 880 63 572 37 ca 0 68 118 195 25...

Страница 29: ...ugh refrigerant line 1 6 Optional feedthrough electric wires 1 7 External dimensions wood design variant 1 8 Included pipe set for optional rear connection of the re frigerant lines 2 Indoor unit 2 1...

Страница 30: ...25 20 15 10 5 0 5 10 15 20 25 30 35 40 max min 0 1 2 3 4 25 20 15 10 5 0 5 10 15 20 25 30 35 40 max min 10 15 20 25 30 35 40 45 50 55 60 65 25 20 15 10 5 0 5 10 15 20 25 30 35 40 Air intake temperatu...

Страница 31: ...ions of nitrogen oxides NOx mg kWh Declared load profile L Water heating energy efficiency wh 87 Daily electricity consumption Qelec 5 66 kWh Daily fuel consumption Qfuel kWh Contact details If Cdh is...

Страница 32: ...eclared load profile L Water heating energy efficiency wh 87 Daily electricity consumption Qelec 5 66 kWh Daily fuel consumption Qfuel kWh Contact details If Cdh is not determined by measurement nthen...

Страница 33: ...overed by the warranty If it was not possible to remedy the defect the manufacturer shall either deliver a replacement free of charge or issue a reimburse ment for the reduced value In cases in which...

Страница 34: ...en cryption methods III Use of service providers Personal data required for maintenance purposes such as your address contact details and framework data on the contract is made available to after sal...

Страница 35: ...www gdts one DOK4x HOIAO WxDEN FD 9912 33 Air to water heat pump 6 kW English 17 Declaration of conformity You can find and download the current CE conformity declaration at https gdts one m...

Страница 36: ...9 dimplex gdts one www gdts one Gesch ftsstelle sterreich Glen Dimplex Austria GmbH Hauptstra e 71 A 5302 Henndorf am Wallersee T 43 6214 20330 F 43 6214 203304 info dimplex at www dimplex at Office F...

Отзывы: