40
Displaying Special Statuses
The corresponding heater display alternates between two characters depending on the status.
Event
Heater
status
Start
conditions
End
conditions
Action
Heater
Display fore
(1 sec.)
Heater
Display back
(1 sec.)
Priority
Heater with residual
heat
Off
Heater
Temperature > 50ºC
Heater
Temperature < 40ºC
----------
‘H’
‘H’
3
Heater without pan
On
No pan or not suitable
pan over the heater
Heater Off
In 1 minute
Heater off
‘Power’
‘υ’
1
Induction generator
over temperature
Off
Heat sink
Temperature > 90ºC
Heat sink
Temperature < 80ºC
----------
‘ ’ or ‘H’
‘c’
2
Induction generator
over temperature
On
No power is
delivered to
the heater
‘Power’
Errors/Alarms
The corresponding heater display alternates between two characters depending on the Error.
APPLIANCE ERRORS
Event
(Visualization Priority Order)
Description
Action
End
All Heater Displays
(fore 0.5 sec./ back 0.5 sec)
FalloKeyOnOffEmitter
Security Key Error
App Off (*)
----------
FA
FalloKeyOnOffReceiver
Security Key Error
App Off (*)
----------
FC
FalloNtcShort
Touch NTc Error
App Off (*)
----------
FE
FalloNtcOpen
Touch NTc Error
App Off (*)
----------
FP
FalloOverTemp
Touch NTc Error
App Off (*)
T < 90ºC
Fc
FalloEepromChecksum
Eeprom Checksum Error
App Off (*)
----------
FH
FalloAdc
Security Key Error
App Off (*)
----------
FJ
FalloSw
Software Error
App Off (*)
----------
F0
FalloAmbientLight
Keyboard Error
App Off (*)
Light Condition
FL
FalloDivisor
Security Key Error
App Off (*)
----------
FU
FalloTestLedOnOff
OnOff Led Error
App Off (*)
----------
Fd
FalloTetGroupSelection
Keyboard Error
App Off (*)
----------
Fb
(*) All heaters switched Off and locked
HEATER ERRORS
Event
(Visualization Priority Order)
Description
Action
End
Heater Display
(fore 0.5 sec./ back 0.5 sec)
FalloComunicaciones
Communication Error
Induction Heaters Off(**) Comm. OK
F5
FalloNtcFocoShort
Induction Heater Ntc Error
Heater Off(**)
Serial Comm.
F1
FalloNtcFocoOpen
Induction Heater Ntc Error
Heater Off(**)
Serial Comm.
F2
FalloNtcFoco
Induction Heater Ntc Error
Heater Off(**)
Serial Comm.
F7
FalloNtcGeneradorShort
Induction Ntc Error
Generator Off (***)
Serial Comm.
F3
FalloNtcGeneradorOpen
Induction Ntc Error
Generator Off (***)
Serial Comm.
F4
FalloNtcGenerador
Induction Ntc Error
Generator Off (***)
Serial Comm.
F8
FalloNoRedGenerador
Induction Error
Generator Off (***)
Serial Comm.
F6
FalloOverLoadGenerador
Induction Error
Generator Off (***)
Serial Comm.
F9
(**) Heater switched off and locked
(***) Generator Heaters switched off and locked
3PCLIOBIM64CGG
06 luglio 2020
Содержание GTI640LWH
Страница 4: ...4 F F E B A D C Fig 8 Fig 9 Fig 6 Fig 7 Ⓐ Ⓑ Fig 5 ...
Страница 41: ...41 NOTE ...
Страница 42: ...42 NOTE ...
Страница 43: ...43 NOTE ...
Страница 44: ...3PCLIOBIM64CGG 02 07 2020 ...