17
FINAL CHECK
Operate all cooker burners on high and low flames and
check that each burner ignites properly and has a stable
flame. The following may be considered to be abnormal:
•
If the burners have yellow tipping.
•
If the pots are sooting up underneath.
•
If the burners are extinguished by opening and closing
the oven door.
•
If the burners fail to ignite properly.
•
If the burners fail to remain alight.
•
If the electrodes constantly click when burners are alight.
When satisfied with the operation of the cooker, please explain
to the user the correct method of operation. If the cooker fails
to operate correctly, contact your local service agent.
GAS CHECKS AND ADJUSTMENTS - IGNITER OPERATION
Check that the igniter for each burner successfully ignites
the gas and that the burner remains alight. If an igniter fails
to work or a burner fails to remain alight, first remove the
plug from the electrical power outlet, and then check that
all the electrical connections are in place. If the upright
cooker fails to operate correctly, call Glem Gas Appliances
Pty Ltd or their appointed agent for service.
DO NOT ATTEMPT REPAIRS YOURSELF.
GAS CHECKS AND ADJUSTMENTS - PRESSURE ADJUSTMENT
First shut off the gas to the appliance. Remove the sealing
screw from the regulator test point at the rear of the cooker
and attach the hose from the mamometer to the point.
Turn the gas back and light the largest burner and smallest
burner at the maximum setting. Check the pressure and
adjust at the regulator if necessary to the settings in the
table or on the data plate. For propane gas adjust at the
regulator at the cylinder. Turn regulator adjusting screw
clockwise to increase pressure and anti clockwise to reduce
pressure. Refit the test point sealing screw when finished.
GAS CONVERSION
If the appliance is to be used with another gas type, either
Propane Gas or Natural Gas, it must be converted by an
Authorised Person. Contact Glem Gas Australasia Pty Ltd or
their authorised agent for details.
The tables below shows the appropriate injector sizes for
either Propane Gas or Natural Gas.
IMPORTANT:
After conversion check the GAS PRESSURE
and IGNITER OPERATION for the Burners. If the upright
cooker cannot be adjusted to perform correctly, or if there
is excessive flame discolouration, yellow tipping or
excessive noise contact Glem Gas Australasia Pty Ltd or
their authorised agent for advice.
T
A
BL
E F
O
R T
H
E CHOICE OF
INJ
ECT
O
RS
NAT
URAL
UL
PG
BURNER T
YPE
Inj
Dia
m
MJ/H Gas
P
ress
Inj
Dia
m
MJ/H Gas
P
ress
W
o
k B
u
rn
er
1.70 13.0
1.0
0.96
11.5
2.75
F
ish
B
u
rn
er
1.55 11.5
1.0
0.88
10.0
2.75
La
rg
e
B
u
rn
e
r
1.55 11.5
1.0
0.88
10.0
2.75
Medi
um
B
u
rn
er
1.18
7.0
1.0 0.68 6.0
2.75
S
m
all Bu
rn
er
0.90
4.0
1.0 0.52 3.5
2.75
53/70/60
cm
Oven
b
u
rn
e
r
1.41
9.0
1.0 0.79 8.5
2.75
80cm
/90cm
Oven
B
u
rn
er
1.75 14.5
1.0
0.95
12.5
2.75