![gledhill PCA 200 - SOL Скачать руководство пользователя страница 5](http://html.mh-extra.com/html/gledhill/pca-200-sol/pca-200-sol_addendum-manual_2231191005.webp)
Page 5
pulsa
c
oil
a
-cl
ass
sol
1.0 design
1.2 tecHnical data
Technical Specification of PulsaCoil SOL A-Class
Models
PCA200 - SOL
PCA220-SOL
PCA240-SOL
Overall dimensions
Height
(mm)
1330
1500
1465
Width
(mm)
560
560
580
Depth
(mm)
605
605
620
Minimum cupboard
dimensions
Height
(mm)
2080
2250
2215
Width
(mm)
600
600
620
Depth
(mm)
625
625
640
Hot and cold water
(mm)
22
22
22
Solar Pipe Connections
Collector
(mm)
15
15
15
Return
(mm)
22
22
22
Maximum hot water flow rate
(l/min)
35
35
35
Weight
Empty
(kg)
60
63
68
Full
(kg)
224
254
278
Dwelling Type
Bedrooms
1-2
2-3
2-3
Bathrooms
1 or
1
1
En-suite
1
1
2
Maximum system pressures
Thermal Store
Open
Vented
6m
6m
6m
Solar System
(bar)
6
6
6
Mains pressure hot water
(bar)
5
5
5
SAP 2005 Data
Storage Volumes
Total
(litres)
164
191
210
Solar
(litres)
53
64
68
Heat loss factor
(kWh/24h)
2.022
2.052
2.086
Temperature factor (vessel heat loss)
-
1. This flow rate is based on a 35ºC temperature rise and assumes that the
recommended pressures and adequate flow are available at the appliance. The actual
maximum flow rate is regulated to a maximum of 26 litres/minute.
2. The temperature of hot water is also regulated to about 52ºC at a flow rate of 18
litres/min.
3. The heat losses from thermal stores should not be directly compared with heat
losses from unvented or vented cylinders because they are treated differently in SAP.
The SAP calculator takes account of the type of store and various correction factors
are included to reflect the different ways that the hot water and heating operates.
For any further technical information/assistance regarding this product please ring
the Gledhill Technical Help line on 01253 474401.
Содержание PCA 200 - SOL