79032998 A Rev.
01-35
General Information
FIG. 72: To adjust the times, rotate either of the rotary
switches (1) until the notch in the switch is over the
desired time. The recommended settings for the auto lube
system is two minutes of on time every 6 hours. Use the
following tables to adjust the times.
After the desired intervals are set, install the sealing plug
in the pump housing.
Auto Lube Interval Settings Table
* Recommended Setting
FIG. 72
N524797
1
Off Time
Rotary
Switch
Setting
Interval
Between
Lube
Cycles
On Time
Rotary
Switch
Setting
Pump will
run for:
0
will not
run
0
will not run
1
1 hour
1
2 minutes
2
2 hours
2*
4 minutes
3
3 hours
3
6 minutes
4
4 hours
4
8 minutes
5
5 hours
5
10 minutes
6*
6 hours
6
12 minutes
7
7 hours
7
14 minutes
8
8 hours
8
16 minutes
9
9 hours
9
18 minutes
A
10 hours
A
20 minutes
B
11 hours
B
22 minutes
C
12 hours
C
24 minutes
D
13 hours
D
26 minutes
E
14 hours
E
28 minutes
F
15 hours
F
30 minutes