42
Material Ratio:
1:1 (Fixed)
Material Viscosity:
200- 2000 Centipoise (Cps) @ AMBIENT
Output:
Pumps Rated:
.042 Gallons Per Cycle
.159 Liters Per Cycle
Operating Temperatures:
32º F ( 0º C ) - 180º (82 º C )
Operating Psi:
22:1 RATIO 2200 PSI @ 100 PSI Air
Max Working PSI 2420 PSI
Note: Overpressure switches are factory set at 2200 PSI.
Purging:
Constant
Automatic Pneumatic, Solvent-free, Constant
Electrical Requirements:
50 A @ 208/240 VAC,50/60 hz, Single Phase
20 A @ 208/240 VAC,50/60 hz. Three Phase
20 A @ 380 VAC, 50 hz. Three Phase
Compressed Air Requirements:
Base Unit:
1.0 GAL PER MINUTE – 17 CFM @ 100 PSI.
1.5 GAL PER MINUTE – 24 CFM @ 100 PSI.
2.0 GAL PER MINUTE – 33 CFM @ 100 PSI.
NOTE:
As output is increased, (achieved w/ chamber
size on gun or spray tip), pressure drop will be greater.
Heating capability will also drop.
Heaters:
6000 WATT HEATER
Maximum Hose Length:
300’
(Each Section 50’ x 3/8” I.D.)
Shipping Weight:
440 Lbs.
Overall Dimensions:
Section 4 - Warranty and Reference Information: Technical Data
Содержание GUARDIAN A6-6000
Страница 25: ...23 REVISION E Section 3 General Information Assembly Drawings 23675 XX Unit Assembly...
Страница 26: ...24 REVISION E Section 3 General Information Assembly Drawings 23675 XX Unit Assembly...
Страница 28: ...26 REVISION E Section 3 General Information Assembly Drawings 23675 XX Generic System Schematic...
Страница 29: ...23675 XX System Schematic 220V Single Phase 27 Section 3 General Information Assembly Drawings REVISION E...
Страница 30: ...23675 XX System Schematic 220V Three Phase 28 Section 3 General Information Assembly Drawings REVISION E...
Страница 31: ...23675 XX System Schematic 380V Three Phase 29 REVISION E Section 3 General Information Assembly Drawings...
Страница 32: ...Section 3 General Information Sub Assembly Drawings 30 REVISION D 23450 XX Hybrid Assembly...
Страница 43: ...Section 4 Safety Information Notes 41...