Page 8 of 27
02.02.2016
7179761000/ Index 03 / DCN 21969
de
en
fr
tr
el
es
pt
da
nl
no
sv
pl
cs
hu
Junction
box
FL60
:
Material Polycarbonat
Junction
box
FL60N
:
Material: Aluminum die cast alloy
Junction
FL60S
:
approved connector, Material Polyamide, mounted
in the housing,
Operation
The input voltage must be disturbance-free within the indicated tolerances for
disturbance-free line operation. To eliminate disturbance effects, no other
consumers may be connected to the power supply line for the floodlight and
operated. We also recommend 3-phase operation.
The floodlight, in particular heat sink and lamp covers of the modules, must al-
ways be kept in a clean condition.
FL60, FL60N
:
To prevent impermissible heating e.g. in case of direct sunlight, a two-stage
temperature control is provided, which reduces the power upon reaching fixed
defined temperatures. The switching values in respect to an optimum service life
of the LED are defined. The power is increased again if the temperature drops.
Temperature Power
Rise to 75°C
50%
Rise to 85°C
25%
Drop to 80°C
50%
Drop to 70°C
100%
Table 2 Temperature control
FL60S4
:
The electronic is temperature controlled.