5
3.
LOW VOLTAGE AND HIGH VOLTAGE
: Use an AC plug inline voltage
monitor. Various areas in Canada and U.S experience severe voltage fluctuates below
110 volts, and as high as 140 volts. The generator must receive between 108V and
125V to operate properly.
4.
POWER EXTENSION CORDS
: Always use three-wire (minimum 14 gauge)
extension cords not over 25-feet in length; if over 25-feet then use 12 gauge wire.
Never extend more than 50-feet. Check the “NEEDS” rating on the label on the
machine to determine the right power supply.
5.
AUXILIARY POWER PLANTS:
Always oversize by 50%. Never under-size. DO NOT GUESS.
Always use heavy enough power cords.
Always purchase a reliable power plant.
SURGING WILL DAMAGE THE EQUIPMENT AND IS NOT
COVERED UNDER WARRANTY.
CAUTION IMPORTANT! Always use a 3-wire circuit analyzer /
tester
before
plugging in the machine(s). If you cannot find an outlet
correctly wired, then DO NOT attempt to use the machine. If extension cords are
required, always us a #14 extension cord. DO not exceed over 25-feet in length.
FAILURE TO DO THE ABOVE COULD SEVERELY DAMAGE YOUR
SYSTEM AND VOID THE WARRANTY.