9
Installation (continued)
6
Installing the plaster guard
Place the plaster guard (L) onto the valve body (D)
and secure with the screws (K).
□
5
Flushing the water outlets
□
and checking for leaks
Place the handle (F) on the valve body (D)
inverter and turn the handle (F) to the full on
mixed position. Turn on the hot and cold water
supply lines and allow the water to flow from
the outlets for one minute, or until all foreign
matter has been flushed out. Check for leaks.
Shut off the water at the faucet and supply
lines.
Check for leaks.
Remove the handle (F).
□
Make sure the stop valves (1) are fully open.
If the stop valves (1) are closed, you must fully
open the stop valves (1) with the flathead
screwdriver.
□
NOTE:
Be sure to position the plaster guard (L) correctly
onto the valve body (D), with the side marked "SHOWER"
facing upward.
4
Back to back installation
NOTE:
Never install the valve body (D) upside down!
□
If the hot and cold inlets are reversed (hot on
right and cold on left), remove the sleeve (1),
and bonnet nut (2) from the valve body (D) with
reversed supply connections. Rotate the
cartridge (3) 180°, so H appears on the right.
Install the cartridge making sure that the key is
fully engaged with the slot in the valve body (D).
Slide the bonnet (2) over the cartridge (3) and
thread them onto the valve body (D). Hand
tighten securely. Reassemble the sleeve (1). If
you are not making a reverse or back to back
installation, skip this step and continue with
the step 5.
HOMEDEPOT.COM/GLACIERBAY
Please contact 1-855-HD-GLACIER for further assistance.
F D
Normal
installation
(changes
not required)
Reverse
installation
Normal installation
Reverse installation
D
Hot
Hot
Cold
Cold
3
2
1
Cold
Hot
D
L
K
1
1
NOTE:
Check for leaks
:
a. Turn off the integral stops, check if there are any leaks
on both of the inlet water supply connections.
b. Fully turn on the integral stops and use plug/cap to
block the outlets of shower head and spout, then turn on
the water and check if there are any leaks on the outlet
pipe/tube connections or elbows.