16
Note: The Self-clean function sanitizes internal waterways. It does not sanitize outside of the faucets
and other external parts of the cooler.
General Cleaning
Perform: As needed (every 6 months under normal conditions)
Time Required: 5 minutes.
Note: Do NOT use abrasive materials or chemical cleaners.
1. Unplug power cord from wall outlet.
2. Clean cabinet surfaces with a soft cloth and warm soapy water.
3. Wipe dust from back of dispenser to improve efficiency.
4. Remove drip tray assembly by sliding it forward. Remove cover. Wash drip tray and grice by hand
with soapy water.
5. Wipe stainless steel parts of the cabinet with unscented Baby oil (mineral oil).
Sanitizing
Probe assembly can be contaminated by touching. please clean
it using procedure described below:
Perform: Half Yearly if required.
Time Required: 15 minutes.
Note: Do it prior to loading a fresh bottle.
1. To clean the probe assembly, unplug power cord from wall outlet.
2. Move combination unit away from wall and turn it 90 degrees in
either direction.
3. Turn power switches to OFF.
4. Remove water bottle and probe from water bottle.
5. Place a 2 gallon or larger bucket under the probe assembly.
6. Remove air filter and wash in soapy water, or use cleaning
solution by dissolving one tablespoon of unscented household
bleach in one gallon of water.
7. Submerge probe in water and wash by hand if dirty. Rinse
properly by submerging in water.
8. Use a spray bottle to spray dispensing nozzles of water faucets
with a chlorine solution.
9. After 1 minute, rinse by spraying the nozzles with tap water.
10. Place probe into bottle filled with tap water. Install in cooler and
close door.
11. Dispense 1 Gallon of water from both faucets.
12. Remove bottle with tap water.
13. Install bottle with fresh water.
14. Dispense 1 gallon of water from both faucets.
15. If bleach smell still present repeat rinsing cycle.
16. Drain an water through drain plug at the back as deseribed.
17. Replace plug.
18. Place bottle with bottled water. Place probe into bottle.
19. Close the door and plug power cord into well outlet.
PROPER CARE & CLEANING
Air Filer
Stainless Steel
tube for Self - Clean
function
Expandable telescopic
tube for drawing water
from the bottle