background image

 

WARNING: 

Always make the appropriate checks to ensure that the surface you are 

drilling does not contain mains electrical wiring or plumbing. Failure to do so can 
result in injury or death by electric shock. 

6)

 

Feed the cable(s) through the grommet(s) and fix the unit in your chosen location 

using appropriate fixings (not supplied). 

 

Connect 

Caution:

 To prevent damage to your mini Opal or lighting controller, switch off the 

power before making connections. 

1)

 

Connect the +, A, S and - wires to the screw-terminal block on the back of the sensor 

PCB. 

A S +

 

Figure 6: Rear of PCB with Output Connections 

1)

 

Optionally connect the tamper output on the top PCB to your alarm system. 

Note: The twin tamper switches provide a single volts-free, normally-closed alarm 
output once the mini Opal is mounted to the wall and the cover is fitted. 

 

Figure 7: mini Opal Tamper Board 

1)

 

If required, see 

Connect External Buzzer or Relay

 (on page 5). 

When the power is applied, the red LED flashes for 0.5 seconds before stopping. The 
LED is normally off during operation. 

 

Содержание mini Opal

Страница 1: ...5 vertical aim adjustment Conformally coated electronics for enhanced UV and moisture resilience Attractive 21st century styling with a protective cover to disguise sensor direction Field of View The...

Страница 2: ...5 Figure 2 Sensor 3m high 0 degree tilt 30m range 6 Metres 6 0 10 20 30 15 Figure 3 Sensor 6m high 9 degree tilt 30m range Pet Immunity lower lenses blanked 1 5 0 10 20 30 5 Figure 4 Sensor 1 5m high...

Страница 3: ...definitely Mount 1 Choose a mounting position it should Be 60cm 2ft from lamps If possible allow the wiring to be run through the wall Be smooth enough to hold the tamper plate in position and provide...

Страница 4: ...f the power before making connections 1 Connect the A S and wires to the screw terminal block on the back of the sensor PCB A S Figure 6 Rear of PCB with Output Connections 1 Optionally connect the ta...

Страница 5: ...relay is connected to the A connection it will trigger for every detection and deactivate immediately By connecting the relay to the S connection the external relay stays active from 60s following the...

Страница 6: ...the smooth rear side of the lens 3 Adjust the range between 9 and 30 metres using the PCB mounted pot 9 5 lux 30m 24hr Figure 10 Range and lux potentiometers Dusk Adjustment Adjust the lux level for t...

Страница 7: ...switch output Tamper switches Case open and removal from wall Power 9 to 15V DC Current 4mA at 12V Operating Temperature 20 C to 55 C Protection IP55 high impact ABS housing Conformal coated electron...

Страница 8: ...ited Sales 44 0 1706 363998 Technical 44 0 1706 363990 Fax 44 0 1706 363991 E Mail info gjd co uk Web http www gjd co uk GJD Reserve the right to amend specifications without notice Copyright 2007 GJD...