ALARM SETTINGS
All alarm settings are made in the events tab. The D-Tect IP works on the principle “Alarm - Action”. This means that
alarms are created based on all types of input signals. For each alarm it is possible to create one or more actions. The
actions can be a network alarm message or to trigger a relay.
Alarm inputs
1.
Go to events tab.
2.
Press “Add Event tab”.
3.
Enter a unique alarm name.
4.
From the Input dropdown menu, choose the action to generate the alarm.
Delay
Alarm delay specifies the time for which the alarm conditions must be continuously fulfilled
before the alarm is enabled. Default value is 0 seconds, maximum is 120 seconds.
Timeout
Timeout specifies the time before the alarm is disabled after the alarm conditions are no longer
met. Default value is 0 seconds, maximum is 120 seconds.
Alarm activation
Always – Always active
Above light limit – Will become active when LUX level is above the light limit setting.
Below light limit – Will become active when LUX level is below the light limit setting.
Light limit
This is the light level (LUX) that the Above light limit and Below light limit react.
6.
Press the Add event button to save.
7.
Repeat step 2 to 6 for all required alarm actions.