PROGRAMMING - USING PROGRAMMING BUTTON

General connection 

1. 

Connect the network cable and verify that the unit powers up and that the network connection is working. 

Factory reset 

1. 

Disconnect the network cable.

2. 

Press and hold the reset button, while reconnecting the network cable.

3. 

The unit will change IP address to the default IP and login.

4. 

The unit will restart in the bootloader. 

USER INTERFACE

Settings are made through the web based user interface. All that is needed is a modern web browser to access and 

change settings . 

The instructions for the user interface described below are valid for firmware 1.32.

FACTORY DEFAULT SETTINGS

When using the system for the first time, or if a factory reset has been made, the following settings are used:

Product IP number 

  192.168.0.10

Subnet mask

 

255.255.255.0

Default router

 

192.168.0.1

Login

1. 

Open a web browser.

2. 

In the address field, type in the selected unit’s IP-address. Default is 192.168.0.10.

3. 

The user interface login page is shown. 

4. 

The user is prompted to create a username and password based on the password policy.

Содержание D-TECT 3 IP GJD260

Страница 1: ...ed TOP D TECT 3 IP GJD260 IP Motion Detector PACKAGE CONTENTS 1 x D TECT 3 IP 1 x Drilling template for fixing holes 3 x 31 75mm wall plugs 3 x 31 75mm screws 2 x Spare sliding curtains 2 x Tamper fee...

Страница 2: ...er of times for the required new setting 5 The indicator blinks twice and the changes are stored in the D TECT 3 IP s non volatile memory Example To change the LED setting from OFF to ON 1 Press the p...

Страница 3: ...O 20 METRE SECTION 11 0 5 15 1 5m 2 deg 30 10 25 20 MASK THIS SECTION OFF FOR PET ALLEY APPLICATIONS UP TO 25m 0 5 10 15 20 25 30 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 m 0 2m 4m 6m 8m 10m 12m 2m...

Страница 4: ...ely when you install or service it Exercise care not to bump the product against nearby objects or drop it inadvertently Caution Only use approved Power over Ethernet power supplies Never try to power...

Страница 5: ...sed user interface All that is needed is a modern web browser to access and change settings The instructions for the user interface described below are valid for firmware 1 32 FACTORY DEFAULT SETTINGS...

Страница 6: ...of the detectors settings use the drop down boxes to select the required setting changes are saved automatically 4 To enable walk test mode press the Walk test ON button and to disable walk test mode...

Страница 7: ...backup purposes and to copy the settings to other units IP address and Login settings are not included in this file 1 Open the import and export settings tab 2 Export all current alarm settings and I...

Страница 8: ...ng a setting file will overwrite all current settings FIRMWARE UPDATE The D Tect IP firmware can be updated to add new functions or resolve software issues 1 Open the Firmware update tab The current f...

Страница 9: ...me for which the alarm conditions must be continuously fulfilled before the alarm is enabled Default value is 0 seconds maximum is 120 seconds Timeout Timeout specifies the time before the alarm is di...

Страница 10: ...off when the alarm clears Output 2 This turns output 2 on when the detector is activated and turns it off when the alarm clears Partner list The products listed have a built in wizard in the D Tect I...

Отзывы: