![GITER G2500-24 Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/giter/g2500-24/g2500-24_installation-manual_2229397005.webp)
05
06
Error code:
2.3 Limitation of liability
2.4 Installation of the battery
2.4.1 Installation site and environment
2.4.2 Unpacking the box
LED outer light
Error code
Description
Troubleshooting
Red light
flickers every
3 seconds.
Error 01
Error 05
Error 07
Error 08
Error 09
Error 10
Error 11
Error 12
Error 13
Any product damage or property loss caused by the following conditions Giter does not assume any
direct or indirect liability.
Product modified, design changed or parts replaced without Giter authorization;
Changes, or attempted repairs and erasing of series number by non Giter technician;
System design and installation are not in compliance with local standards and regulations;
The product has been improperly stored in dealer’s or end user’s premises;
Transport damage (including painting scratch caused by movement inside packaging during the
shipping). A claim should be made directly to shipping or insurance company as soon as the
container/packaging is unloaded and such damage is identified;
Failure to follow any/all of the user manual, the installation guide and the maintenance
regulations;
Improper use or misuse of the device;
Insufficient ventilation of the device;
The maintenance procedures relating to the product have not been followed to an acceptable
standard;
Force majeure (violent or stormy weather, lightning, overvoltage, fire etc.).
Damages caused by any external factors.
LED display
Temperature
sen-sor failure
DIP switch
mode difference
BMS disconnect
(slave)
BMS disconnect
(master)
Software version
inconsistent
MOSFET over
temperature
Multi master
SN missing
MOSFET error
Please restart the
battery.
If the problem is not
resolved, please
contact GITER after
sales team.
Please keep
consistence of DIP
switches then restart
the system.
Please reconnect the
communication cable.
Please contact
GITER after sales
team.
Please reconnect the
communication cable.
Please contact Giter
after sales team.
After shutting down
the battery system,
please restart all
batteries within 30s.
Please turn off the
battery and turn on
the battery after
about 2 hours.
This manual describes the basic steps of how to install and set up.
Take out the battery from the packing box and check whether the accessories are complete, as
shown in Figure 2.
The following location are not allowed for installation:
• sites with high humidity, or where there is condensation;
• sites which are salty and where humid air can penetrate;
• flooded areas.
• earthquake areas –additional security measures are required here;
• sites with explosive atmosphere;
• sites with direct sunlight;
• sites with extreme change of ambient temperature;
• sites with highly flammable materials or gases;
• sites with a potentially explosive atmosphere.