GITER G2500-24 Скачать руководство пользователя страница 5

05

06

Error code:

2.3  Limitation of liability

2.4 Installation of the battery

2.4.1 Installation site and environment

2.4.2 Unpacking the box

LED outer light

Error code

Description

Troubleshooting

Red light

 flickers every 

3 seconds.

Error 01

Error 05

Error 07

Error 08

Error 09

Error 10

Error 11

Error 12

Error 13

Any product damage or property loss caused by the following conditions Giter does not assume any 
direct or indirect liability.

      

Product modified, design changed or parts replaced without Giter authorization; 

      

Changes, or attempted repairs and erasing of series number by non Giter technician; 

      

System design and installation are not in compliance with local standards and regulations;  

      

The product has been improperly stored in dealer’s or end user’s premises; 

      

Transport damage (including painting scratch caused by movement inside packaging during the 

     shipping). A claim should be made directly to shipping or insurance company as soon as the 
     container/packaging is unloaded and such damage is identified; 

       

Failure to follow any/all of the user manual, the installation guide and the maintenance 

     regulations; 

       

Improper use or misuse of the device; 

       

Insufficient ventilation of the device; 

       

The maintenance procedures relating to the product have not been followed to an acceptable 

     standard; 

       

Force majeure (violent or stormy weather, lightning, overvoltage, fire etc.). 

       

Damages caused by any external factors.

LED display

Temperature 

sen-sor failure

DIP switch 

mode difference

BMS disconnect 

(slave)

BMS disconnect

(master)

Software version

 inconsistent

MOSFET over 

temperature

Multi master

SN missing

MOSFET error

Please restart the 

battery.

If the problem is not 

resolved, please 

contact GITER after 

sales team.

Please keep 

consistence of DIP 

switches then restart 

the system.

Please reconnect the 

communication cable.

Please contact 

GITER after sales 

team.

Please reconnect the 

communication cable.

Please contact Giter 

after sales team.

After shutting down 

the battery system, 

please restart all 

batteries within 30s.

Please turn off the 

battery and turn on 

the battery after 

about 2 hours.

This manual describes the basic steps of how to install and set up.

Take out the battery from the packing box and check whether the accessories are complete, as 

shown in Figure 2.

The following location are not allowed for installation: 
• sites with high humidity, or where there is condensation;
• sites which are salty and where humid air can penetrate;
• flooded areas.
• earthquake areas –additional security measures are required here;
• sites with explosive atmosphere;
• sites with direct sunlight;
• sites with extreme change of ambient temperature;
• sites with highly flammable materials or gases;
• sites with a potentially explosive atmosphere.

Содержание G2500-24

Страница 1: ...G2500 24 Giter Co Ltd T 86 512 6828 7609 E info giter ess com W www giter ess com 808 812 Building 10A Zilang Science and Technology City 60 Chongzhou Avenue Economic and Technological Development Zone Nantong Jiangsu Province 226006 Version V1 1 ...

Страница 2: ...ery 2 3 Limitation of liability 2 4 Installation of the battery 2 4 1 Installation site and environment 2 4 2 Unpacking the box 2 4 3 Installation and wiring 3 System operation 3 1 Power on off 4 Maintenance and fault handling 4 1 Routine maintenance 4 2 Handling of other faults and abnormal phenomena 4 2 1 Unable to turn on 4 2 2 Shut down immediately after turn on 4 2 3 Unable to charge 4 2 4 Un...

Страница 3: ...eaked or toxic gases formed Do not install the system in any environment of temperature below 10 C or over 50 C and in which humidity is over 85 Do not touch the system with wet hands Do not put any heavy objects on top of the system Do not damage the system with sharp objects Do not install or operate the system in potentially explosive atmospheres or areas of high humidity Do not mount the inver...

Страница 4: ...current discharge Cell under voltage 1 1 2 3 4 5 6 7 8 LED outer light State Standby Green light flickers every 1s Work Green light flickers every 10s Green light flickers every 3 seconds LED outer light SOC Description SOC 5 5 SOC 25 25 SOC 50 50 SOC 75 75 SOC 95 SOC 95 Charging in low temperature environment Discharging in low temperature environment It s actually in normal working mode when the...

Страница 5: ...een followed to an acceptable standard Force majeure violent or stormy weather lightning overvoltage fire etc Damages caused by any external factors LED display Temperature sen sor failure DIP switch mode difference BMS disconnect slave BMS disconnect master Software version inconsistent MOSFET over temperature Multi master SN missing MOSFET error Please restart the battery If the problem is not r...

Страница 6: ...t tighten the four angle screws M6 12 screw torque 5 N m and fix the copper busbar between the battery modules with 3 cross screwdriver M8 torque 12 N m Step 1 As shown in Figure 3 fix the hanging ear on both sides of the battery with 4 screws Torque 1 6 N m Tools T20 screwdriver 1 Serial connection between batteries is not allowed 2 The power cable of the cross sectional area connected to the inv...

Страница 7: ...s shown in Figure 9 Step 3 As shown in Figure 5 connect the communication cable and dial code after the connection Switch 2 for the bottom battery and 4 for all other batteries Note The communication wiring between the battery and the inverter has a special sequence The requirements of communication wiring connection are shown in Figure 6 Note A bracket including a left bracket and a right bracket...

Страница 8: ...onnected correctly 3 Check if the battery breaker is ON 4 Check if the ambient temperature is within the operating range If the battery still cannot be charged normally after these steps please contact customer service 4 2 4 Unable to discharge Fault Troubleshooting Description The battery cannot be discharged as it should while it is still alive with no LED protection code nor error code 1 Check ...

Страница 9: ... outer light is always on and the status light is off Turn on the Power switch and hold for 5 seconds Observe the status of the LED outer light If the LED light keeps on after the troubleshooting please contact customer service Nominal voltage Nominal charge discharge current Charging voltage limit Discharge voltage limit Nominal capacity Usable capacity DoD Max Number in parallel Communication in...

Отзывы: