background image

8: Motion detector connection diagram 

Connect controller and optional installation button T, NC contact, according to connection 
diagram ( 8). 

If multiple motion detectors are to switch a shared load, connect the motion detectors in 
parallel.  

Parallel switching of multiple motion detectors does not increase maximum connected load. 

9: Connection diagram, switching off motion detectors 

The motion detector can be switched off using installation switch S1 or S2 ( 9). Switching 
installation switch S1 on again triggers switch-on for the follow-up time. Installation S2 does not 
do this. 

82523522 

19.05.2011 

6/8 

Observer 70 

Содержание Observer 70

Страница 1: ...take into account all circuit breakers that supply dangerous voltage to the device or load Do not press on the sensor window Device can be damaged The device is not suitable for use as a burglar alarm...

Страница 2: ...e to the cooling of a bulb the controller does not evaluate any signals for approx 3 seconds after switch off 2 Detection area motion detector 4 Operation Switching the light on manually Optional inst...

Страница 3: ...er e g rain fog or snow The range is increased in the case of The land slopes downwards away from the motion detector High temperature difference Installation height greater than 2 4 m o Select a vibr...

Страница 4: ...ble closure of the condensation water hole 8 o Run the connection cable into the connection compartment through a rubber sleeve 4 o Fasten the rear housing panel on the installation location with two...

Страница 5: ...Minimum range o Measure the detection area by walking it To do this switch the motion detector to test mode Set the follow up time to 10 seconds and the brightness value to 3 Connecting the controlle...

Страница 6: ...the motion detectors in parallel i Parallel switching of multiple motion detectors does not increase maximum connected load 9 Connection diagram switching off motion detectors The motion detector can...

Страница 7: ...on time approx 10 s 5 min Connected load Incandescent lamps 1000 W HV halogen lamps 1000 W Tronic transformers 750 W Inductive transformers 750 VA Electronic ballast Type dependent Fluorescent lamps...

Страница 8: ...o Installations Systeme Industriegebiet Mermbach Dahlienstra e 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 399 www gira de info gira de 825...

Отзывы: