4: Rear housing panel and installation frame 

To prevent the ingress of moisture, we recommend inserting the cables from below (10). 

When the cables enter below, use an installation frame (9). Insert the rear housing panel 
(7) into the installation frame. 

Do not use an installation frame for surface cable entry from the side or from above, but 
instead penetrate one of the the thinner areas of the rear housing panel. 

Do not remove the water-permeable closure of the condensation water hole (8). 

Run the connection cable into the connection compartment through a rubber sleeve (4). 

Fasten the rear housing panel on the installation location with two screws (6) in such a way 
that the condensation water hole is at the bottom. 

Configuring the motion detector 

On the rear side of the housing cover of the motion detector, there is one adjuster each for the 
follow-up time (11) and the brightness threshold (12) ( 5).  

5: Setting the follow-up time and the brightness threshold 

The range of the motion detector can be set in three stages by sliding the internal housing (13) 
( 6). 

82523522 

19.05.2011 

4/8 

Observer 70 

Содержание Observer 70

Страница 1: ...take into account all circuit breakers that supply dangerous voltage to the device or load Do not press on the sensor window Device can be damaged The device is not suitable for use as a burglar alarm...

Страница 2: ...e to the cooling of a bulb the controller does not evaluate any signals for approx 3 seconds after switch off 2 Detection area motion detector 4 Operation Switching the light on manually Optional inst...

Страница 3: ...er e g rain fog or snow The range is increased in the case of The land slopes downwards away from the motion detector High temperature difference Installation height greater than 2 4 m o Select a vibr...

Страница 4: ...ble closure of the condensation water hole 8 o Run the connection cable into the connection compartment through a rubber sleeve 4 o Fasten the rear housing panel on the installation location with two...

Страница 5: ...Minimum range o Measure the detection area by walking it To do this switch the motion detector to test mode Set the follow up time to 10 seconds and the brightness value to 3 Connecting the controlle...

Страница 6: ...the motion detectors in parallel i Parallel switching of multiple motion detectors does not increase maximum connected load 9 Connection diagram switching off motion detectors The motion detector can...

Страница 7: ...on time approx 10 s 5 min Connected load Incandescent lamps 1000 W HV halogen lamps 1000 W Tronic transformers 750 W Inductive transformers 750 VA Electronic ballast Type dependent Fluorescent lamps...