1 Safety instructions 

Electrical equipment may only be installed and fitted by electrically skilled persons. 

Failure to observe the instructions may cause damage to the device and result in fire and 
other hazards. 

Danger of electric shock. Device is not suitable for disconnection from supply voltage. 

Danger of electric shock. Always disconnect before carrying out work on the devise or 
load. At the same time, take into account all circuit breakers that supply dangerous 
voltage to the device or load. 

Do not press on the sensor window. Device can be damaged. 

The device is not suitable for use as a burglar alarm or other alarm. 

These instructions are an integral part of the product, and must remain with the end 
customer. 

2 Device components 

(1)  Sensor window 
(2)  Rear device panel 
(3)  Central screw 

3 Function 

Intended use 

Automatic switching of lighting depending on the heat motion and ambient brightness. 

Surface-mounting in indoor and outdoor areas 

Product characteristics 

Variable installation position 

Protected against spray water 

1/8 

82523522 

19.05.2011 

Observer 70 

Содержание Observer 70

Страница 1: ...take into account all circuit breakers that supply dangerous voltage to the device or load Do not press on the sensor window Device can be damaged The device is not suitable for use as a burglar alarm...

Страница 2: ...e to the cooling of a bulb the controller does not evaluate any signals for approx 3 seconds after switch off 2 Detection area motion detector 4 Operation Switching the light on manually Optional inst...

Страница 3: ...er e g rain fog or snow The range is increased in the case of The land slopes downwards away from the motion detector High temperature difference Installation height greater than 2 4 m o Select a vibr...

Страница 4: ...ble closure of the condensation water hole 8 o Run the connection cable into the connection compartment through a rubber sleeve 4 o Fasten the rear housing panel on the installation location with two...

Страница 5: ...Minimum range o Measure the detection area by walking it To do this switch the motion detector to test mode Set the follow up time to 10 seconds and the brightness value to 3 Connecting the controlle...

Страница 6: ...the motion detectors in parallel i Parallel switching of multiple motion detectors does not increase maximum connected load 9 Connection diagram switching off motion detectors The motion detector can...

Страница 7: ...on time approx 10 s 5 min Connected load Incandescent lamps 1000 W HV halogen lamps 1000 W Tronic transformers 750 W Inductive transformers 750 VA Electronic ballast Type dependent Fluorescent lamps...

Страница 8: ...o Installations Systeme Industriegebiet Mermbach Dahlienstra e 42477 Radevormwald Postfach 12 20 42461 Radevormwald Deutschland Tel 49 0 21 95 602 0 Fax 49 0 21 95 602 399 www gira de info gira de 825...