background image

DALI Tronic transformer 105 W 

Order-No. : 2380 00 

Operating instructions 

1 Safety instructions 

Electrical equipment may only be installed and fitted by electrically skilled persons. 

Failure to observe the instructions may cause damage to the device and result in fire and 
other hazards. 

Danger of electric shock. Always disconnect before carrying out work on the devise or 
load. At the same time, take into account all circuit breakers that supply dangerous 
voltage to the device or load. 

These instructions are an integral part of the product, and must remain with the end 
customer. 

2 Device components 

Figure 1 

(1)  Fastening screws for terminal cover 
(2)  Mounting holes 
(3)  Terminal covers 

3 Function 

Intended use 

Power supply for LV halogen lamps 

Switching and brightness adjustment is performed with DALI control units or installation 
buttons 

Installation in false ceilings or surface mounting 

Product characteristics 

No-load proof 

Electronic short circuit protection 

Electronic overload protection 

Electronic over-temperature protection 

Suitable for emergency current installation 

1/7 

82575902 

13.05.2011 

DALI Tronic transformer 105 W 

Содержание DALI Tronic Trafo 105 W

Страница 1: ...the device or load These instructions are an integral part of the product and must remain with the end customer 2 Device components Figure 1 1 Fastening screws for terminal cover 2 Mounting holes 3 Te...

Страница 2: ...ghtness value Adjusting brightness with installation button Light is switched on o Make a long press on the installation button Light becomes brighter or dimmer as far as the respective limit value i...

Страница 3: ...must not be exceeded Do not fit in the vicinity of heat sources e g lamps o Loosen screws 1 and remove terminal covers 3 o Fasten transformer with screws through mounting holes 2 Connection instructi...

Страница 4: ...V F 2 1 5mm2 H05VVH2 F 2 0 75mm2 H05VV F 2 2 5mm2 NYM J 3 1 5mm2 NYM J 3 1 5mm2 NYM O 2 1 5mm2 NYM O 2 1 5mm2 NYM J 3 2 5mm2 Figure 3 Stripping lengths o Strip connecting cables according to specifica...

Страница 5: ...ng transformer with installation button Figure 5 Connection diagram with installation button i Illuminated installation buttons may only be connected if they have a separate N terminal i Connect all t...

Страница 6: ...ower loss max 6 W Power factor 0 95 Output voltage AC 11 8 V eff Ambient temperature 20 50 C Housing temperature 75 C tc Protection rating IP 20 Safety class II Primary side connection Single stranded...

Страница 7: ...ease submit or send faulty devices postage paid together with an error description to your responsible salesperson specialist trade installation company electrical specialist trade They will forward t...

Отзывы: