Observer 180 plus 

Installation Instructions 

 

 

Observer 180 plus 

28/99 

Page: 8 of 13 

 

c

d

3 sec

1 min

5 min

15 min

ZEIT

LUX

SENS.

Test

e

 

If no push-button for the additional functions has been installed for 
the 180° observer, the test mode can also be set on the unit. 
 
Select the following for the function test: 

c

 Time setting:           Approx. 3 sec. 

d

 Brightness setting:    Day-time operation. 

e

 Sensitivity:             Individual, please refer to the illustration. 

 
After the function test, you can set the time and brightness value 
as desired. 

 

 

Notes: 

After the observer has switched off, a delay time of 3 seconds must be waited before switching on 
takes place again. 
 
Turning on the mains supply triggers a switching process of the observer. If this is not desired, please 
install an additional switch, as shown in the connection diagram. 
 
When the lighting is off, unfavourable installation conditions may cause reclosing by detection of the 
lamps (cooling down and hence different heat rate), due to reflection of heat radiation from the lighting, 
or due to too close a spacing between the observer and the lighting fixture. In this case, reduce the 
sensitivity. 
 

 

L
N

S

 

Wiring Diagrams 

 
Existing Installation 

 

 

 

BK

BU

BN

T

N

L

 

Connecting the Observer 

 
Replace existing switch 'S' by additional functions push-button 'T' 
(normally closed contact). 
 

For each operation, the push-button must be held pressed for 
at least 200 ms, while the next operation must be done within 
2 seconds. After this, the additional function selected will be 
activated. 

 
 
BK (black):     L 
BU (blue):      N 
BN (brown):   

 

Time 

Содержание 180 plus

Страница 1: ...witch the switching function is activated from a desired brightness value only or can be set to day time night time operation The working range of the unit can be individually adapted by adjusting the...

Страница 2: ...the environment Choosing the Location To obtain an optimum working range install the observer at a height of 2 4 m laterally to the moving direction as otherwise losses in the working range will have...

Страница 3: ...ms The unit is provided with two cable entries The supply and lamp lines can be led into the enclosure separately To lead in the lines pierce respective rubber bushing d Do not cut open the rubber bus...

Страница 4: ...lug on the enclosure top sensor head and secure with the central screw c d e 3 sec 1 min 5 min 15 min ZEIT LUX SENS Test Adjustments Time setting follow up time c within the range of approx 3 seconds...

Страница 5: ...upon the brightness Relay open All LEDs are off Relay closed LED c is lit 2nd Additional Function Pressing the push button twice Light ON The light is switched on for approx 2 hours After this the un...

Страница 6: ...1 min Up to 85 min 30 sec Up to 90 min 15 sec 90 min Switching off Thus even in the event of permanent movements within the detection field the observer switches off after 90 min at the latest Reclos...

Страница 7: ...rwise undesired detection e g thermal movement through open windows may entail erroneous switching c d 3 sec 1 min 5 min 15 min ZEIT LUX SENS Test e Function Test For the function test the slip fit ap...

Страница 8: ...pply triggers a switching process of the observer If this is not desired please install an additional switch as shown in the connection diagram When the lighting is off unfavourable installation condi...

Страница 9: ...load BK black L BU blue N BN brown When observers are connected in parallel only the presently active unit may possibly detect a movement If the room illumination switched on shines on further paralle...

Страница 10: ...igh starting current peaks for energy saving lamps Test the suitability of the lamps prior to use Power consumption Approx 1 1 W Temperature range 25 C to 55 C On period Approx 3 sec to approx 15 min...

Страница 11: ...lling terrain zwith the sensor head tilted up zand at an installation height of more than 2 4 m 34 C 33 C 24 C 26 C ca Moving Heat Sources The observer PIR responds to thermal changes within the detec...

Страница 12: ...of the thermal radiation e g mist reduce the working range 1 2 3 Moving Direction If a person moves square to the observer a negative temperature jump results for ray o e g from 20 C to 18 C and a po...

Страница 13: ...age paid to our central service department giving a brief description of the fault Gira Giersiepen GmbH Co KG Service Center Dahlienstrasse 12 D 42477 Radevormwald The CE sign is a free trade sign add...

Отзывы: