Observer 180 plus 

Installation Instructions 

 

 

Observer 180 plus 

28/99 

Page: 10 of 13 

Specifications 

 
Rated 

working 

range:         16 

Installation 

height:           Approx. 

2.40 

 

Rated 

voltage:             230 

VAC, 

50 

Hz 

Switching 

contact:           Relay 

Starting current:   

                   

Max. 20 A 

Automatic 

cut-out:           10 

 

Switching capacity: 

Incandescent 

lamps          2500 

Halogen 

HV 

lamps 

          2500 

Fluorescent lamps 

Unbalanced:             1200 

Shunt-compensated: 

         

 

920 

 Twin-lamp 

circuit: 

       2400 

 
 

Important: 

Mind high starting current peaks for 'energy-saving lamps'. Test the suitability of the lamps prior to 
use. 
 
 
Power consumption:

                  

Approx. 1.1 W 

 
Temperature 

range:          -25 

°C 

to 

55 

°C 

 
On 

period:               Approx. 

sec. 

to 

approx. 

15 

min., 

continuously 

adjustable 

 
Brightness sensor: 
Day-time and night-time operation     Continuously adjustable 
 
Sensitivity:               Adjustable 

on 

approx. 

20-100% 

 
Additional 

functions:          ON 

for 

hours 

                                        OFF for 2 hours 
                                        Test mode 
 
Protective 

system:           IP 

55, 

hose-proof. 

 

 
Connections:                           L, N, 

  

                                        1.5 mm² line 
 
 

Please hand over these Operating Instructions to your Customer after installation.

 

 

These observers are not sabotage-proof and, therefore, not suitable for use as alarm system.

 

 
 

Содержание 180 plus

Страница 1: ...witch the switching function is activated from a desired brightness value only or can be set to day time night time operation The working range of the unit can be individually adapted by adjusting the...

Страница 2: ...the environment Choosing the Location To obtain an optimum working range install the observer at a height of 2 4 m laterally to the moving direction as otherwise losses in the working range will have...

Страница 3: ...ms The unit is provided with two cable entries The supply and lamp lines can be led into the enclosure separately To lead in the lines pierce respective rubber bushing d Do not cut open the rubber bus...

Страница 4: ...lug on the enclosure top sensor head and secure with the central screw c d e 3 sec 1 min 5 min 15 min ZEIT LUX SENS Test Adjustments Time setting follow up time c within the range of approx 3 seconds...

Страница 5: ...upon the brightness Relay open All LEDs are off Relay closed LED c is lit 2nd Additional Function Pressing the push button twice Light ON The light is switched on for approx 2 hours After this the un...

Страница 6: ...1 min Up to 85 min 30 sec Up to 90 min 15 sec 90 min Switching off Thus even in the event of permanent movements within the detection field the observer switches off after 90 min at the latest Reclos...

Страница 7: ...rwise undesired detection e g thermal movement through open windows may entail erroneous switching c d 3 sec 1 min 5 min 15 min ZEIT LUX SENS Test e Function Test For the function test the slip fit ap...

Страница 8: ...pply triggers a switching process of the observer If this is not desired please install an additional switch as shown in the connection diagram When the lighting is off unfavourable installation condi...

Страница 9: ...load BK black L BU blue N BN brown When observers are connected in parallel only the presently active unit may possibly detect a movement If the room illumination switched on shines on further paralle...

Страница 10: ...igh starting current peaks for energy saving lamps Test the suitability of the lamps prior to use Power consumption Approx 1 1 W Temperature range 25 C to 55 C On period Approx 3 sec to approx 15 min...

Страница 11: ...lling terrain zwith the sensor head tilted up zand at an installation height of more than 2 4 m 34 C 33 C 24 C 26 C ca Moving Heat Sources The observer PIR responds to thermal changes within the detec...

Страница 12: ...of the thermal radiation e g mist reduce the working range 1 2 3 Moving Direction If a person moves square to the observer a negative temperature jump results for ray o e g from 20 C to 18 C and a po...

Страница 13: ...age paid to our central service department giving a brief description of the fault Gira Giersiepen GmbH Co KG Service Center Dahlienstrasse 12 D 42477 Radevormwald The CE sign is a free trade sign add...

Отзывы: