Choice of location 

The minimum protection is one smoke detector on every 
floor (hall or landing area) and in every child’s bedroom. 
It is better, however, to have a smoke detector in every 
room, apart from the kitchen and bathroom, where steam 
can cause false alarms. 

 

 

Fig.1 

 

Fig.2 

The smoke detector must be fixed to the ceiling as near to the 
centre of the room as possible. One detector can monitor a room 
with a maximum floor area of 60 m² with a ceiling height of up to 
6 m. In hallways and narrow corridors (up to 3 m wide) the 
detector monitors a distance of up to 7.5 m in each direction. A 
gap of at least 0.5 m must be maintained from walls and fixtures.

 

You should therefore install: 

  as an absolute necessity one smoke detector in the hallway 

(to monitor the escape route) between living and sleeping 
areas 

  for optimum protection one detector in every living room and 

every bedroom 

  in multistorey buildings at least one detector on each landing

  in converted lofts one detector above the staircase 

 

Installation on the ceilings of boat cabins or caravans is also 
possible. When travelling, simply take the smoke detector with 
you into your hotel room. 

Unsuitable locations 

Never install the smoke detector 

  near to ventilation ducting or strong draughts 

  directly in the apex of pitched roofs (a minimum distance of 30 cm from the apex must be 

maintained) 

  in rooms where there is a lot of steam, dust or smoke under normal conditions (workshops, 

bathrooms, laundry rooms, for example) 

  in rooms where the temperature rises above +40 °C or falls below +5 °C 

  in the vicinity of fluorescent luminaires. 

Installation and putting into service 

 

Fig.3 

The home smoke detector is installed as follows: 

  Remove the smoke detector from its base by turning it 

anticlockwise. 

  Screw the base to the ceiling using the fixing materials 

provided (see Fig. 3 for dimensions). 

  Attach the 9 V rectangular battery to the connector and insert 

it into the battery holder (1). 

  Insert the smoke detector into the base, without using force, 

and turn it gently clockwise until it clicks into place. 

Note:

 If no battery is fitted, the smoke detector will not click 

into place! 

  Finally verify the good working order of the smoke detector 

by pressing ist test button. 

 